Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Setting the Device Fault Indicator

Setting the Device Fault Indicator

Context

The fault indicator status is indicated by mode indicators and the system indicator. When a device becomes faulty, you can configure mode indicators and the system indicator on the device to blink red fast so that maintenance personnel can quickly find this device onsite. Mode indicators include the STAT indicator, SPED indicator, PoE indicator (supported only on PoE switches) and STCK indicator. The system indicator is the SYS indicator, which indicates the system running status.

NOTE:

Only the S1720GW, S1720GWR, S1720X, S1720GW-E, S1720GWR-E, S1720X-E, S2720EI, S5700S-LI (only the S5700S-28X-LI-AC and S5700S-52X-LI-AC), S5710-X-LI, S5720LI, S5720S-LI, S5720S-SI, S5720SI, S5720EI, S5730SI, S5730S-EI, S6720LI, S6720S-LI, S6720SI, S6720S-SI, S6720S-EI, and S6720EI support this function.

Procedure

  1. Run system-view

    The system view is displayed.

  2. Run set device fault-light { normal | under-repair [ keeptime time ] } [ slot slot-id ]

    The fault indicator status of the device is set.

    By default, the fault indicator status of the device is not set. The fault indicator status is displayed based on the current device running status.

    normal indicates that the fault indicator status is displayed based on the current device running status. under-repair configures the fault indicator to indicate that the device is faulty. If keeptime time is not specified, the default time during which the fault indicator indicates that the device is faulty is 45 seconds.

  3. (Optional) Run display device fault-light

    The fault indicator status is displayed.