Configuration Guide - Device Management

S1720, S2700, S5700, and S6720 V200R011C10

This document describes the principles and configurations of the Device Management features, and provides configuration examples of these features.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Setting the Alarm Severity

Setting the Alarm Severity

Context

The system defines default alarm severity for each alarm. Users can change the alarm severity. When receiving alarms reported by a device, the NMS can configure filtering rules to display only alarms of a specified severity.

As defined in X.733, alarms are classified into six severities, as described in Table 5-2. A small value indicates a higher severity.

Table 5-2  Descriptions of alarm severities

Value

Severity

Description

1

Critical

Indicates that a fault affecting services has occurred and it must be rectified immediately.

2

Major

Indicates that services are being affected and related measures need to be taken urgently.

3

Minor

Indicates that a fault occurs but does not affect services. To avoid a minor alarm from getting severer, related measures must be immediately taken.

4

Warning

Indicates that a potential or impending service-affecting fault is detected before any significant effects have been felt. Take corrective actions to diagnose and rectify the fault.

5

Indeterminate

Indicates that the severity of an alarm cannot be determined.

6

Cleared

Indicates that one or more previous alarms have been cleared.

Procedure

  1. Run system-view

    The system view is displayed.

  2. Run alarm

    The alarm view is displayed.

  3. (Optional) Run display alarm information [ name alarm-name ]

    The alarm severity is displayed.

  4. Run alarm-name alarm-name severity severity

    The alarm severity is changed.

    The system has defined default alarm severity for each alarm.