Configuration Guide - Device Management

S1720, S2700, S5700, and S6720 V200R011C10

This document describes the principles and configurations of the Device Management features, and provides configuration examples of these features.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Information Output Format

Information Output Format

  • Log output format

    Figure 4-2 shows the log output format.
    Figure 4-2  Output format of logs
    Table 4-4 describes each field in a log.
    Table 4-4  Description of each field in a log

    Field

    Description

    Remarks

    <Int_16>

    Leading character.

    This character is added to the information to be sent to the log host. It is not added to the information saved locally.

    TimeStamp

    Time log information is output.

    Five timestamp formats are available:

    • boot

      Timestamps in this format are expressed in relative time, specially the period of time since the system starts. The format is xxxxxx.yyyyyy. xxxxxx is the higher order 32 bits of the milliseconds elapsed since the start of the system; yyyyyy is the lower order 32 bits of the milliseconds elapsed since the system starts.

    • date

      Timestamps in this format use the current system date and time. It is expressed in mm dd yyyy hh:mm:ss format.

    • short-date

      Timestamps in this format use the current system date and time. Unlike the date format, the year is not displayed in the short-date format.

    • format-date

      Timestamps in this format are expressed in YYYY-MM-DD hh:mm:ss format.

    Logs use timestamps in the date format by default.

    TimeZone

    Local zone.

    Local time zone information. This information is the same as the Time Zone field of the display clock command output.

    HostName

    Host name.

    -

    %%

    Huawei identifier.

    The log is output by Huawei products.

    dd

    Version number.

    Version number of the log.

    ModuleName

    Module name.

    Name of the module that outputs information to the information center.

    Severity

    Log severity.

    Severity level of the log.

    Brief

    Brief description.

    Brief description of the log.

    (l)

    Information type.

    Information types:

    • l: log

    • S: security log

    • D: debugging log

    DDD

    Log sequence number.

    By default, the information center can output logs to the console, log buffer, SNMP agent, and log file. In the log buffer, the value depends on the log buffer size. For example, the log buffer can store a maximum of 100 logs. The log sequence number ranges from 0 to 99.

    Description

    Description.

    Contents of the log.

  • Trap output format

    Figure 4-3 shows the trap output format.
    Figure 4-3  Trap output format

    Table 4-5 describes each field in a trap.

    Table 4-5  Description of each field in a trap

    Field

    Description

    Remarks

    #

    Information type.

    The number sign (#) indicates a trap and appears only in the trap buffer.

    TimeStamp

    Time trap information is output.

    Five timestamp formats are available:

    • boot

      Timestamps in this format are expressed in relative time, specially the period of time since the system starts. The format is xxxxxx.yyyyyy. xxxxxx is the higher order 32 bits of the milliseconds elapsed since the start of the system; yyyyyy is the lower order 32 bits of the milliseconds elapsed since the system starts.

    • date

      Timestamps in this format use the current system date and time. It is expressed in mm dd yyyy hh:mm:ss format.

    • short-date

      Timestamps in this format use the current system date and time. Unlike the date format, the year is not displayed in the short-date format.

    • format-date

      Timestamps in this format are expressed in YYYY-MM-DD hh:mm:ss format.

    Traps use timestamps in the date format by default.

    TimeZone

    Local zone.

    Local time zone information. This information is the same as the Time Zone field of the display clock command output.

    HostName

    Host name.

    The host name and module name are separated by a space.

    ModuleName

    Module name.

    Name of the module that outputs information to the information center.

    Severity

    Severity.

    Severity level of the trap.

    Brief

    Brief description.

    Brief description of the trap.

    Description

    Description.

    Contents of the trap.