Configuration Guide - Device Management

S1720, S2700, S5700, and S6720 V200R011C10

This document describes the principles and configurations of the Device Management features, and provides configuration examples of these features.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
(Optional) Setting the Timestamp Format of Logs

(Optional) Setting the Timestamp Format of Logs

Context

To adjust the time format and time precision for information output, configure the timestamp.

Procedure

  1. Run system-view

    The system view is displayed.

  2. Run info-center timestamp log { { date | format-date | short-date } [ precision-time { second | tenth-second | millisecond } ] | boot } [ without-timezone ]

    The timestamp format of logs is configured.

    By default, the timestamp format of logs is date and logs are accurate to seconds.