No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

MIB Reference

S7700 and S9700 V200R011C10

This document provides the function overview, relationships between tables, description of single objects, description of MIB tables, and description of alarm objects.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
HUAWEI-DATASYNC-MIB

HUAWEI-DATASYNC-MIB

Functions Overview

HUAWEI-DATASYNC-MIB is a private MIB of Huawei. It mainly implements data synchronization between the Network Management System (NMS) and hosts.

Data synchronization can be classified into incremental synchronization and all-data synchronization. In incremental synchronization, you can query configuration changes through this MIB. In this manner, you can view the maximum number of configuration changes cached in the configuration change table, perform the loop count for configuration changes, and know the ID of the current configuration change. In addition, you can be informed of the configuration change by the relevant alarm. In all-data synchronization, through the MIB, you can set the script file, result file, and NMS ID, and start or stop the collection of configuration changes.

Root directory:

iso(1).org(3).dod(6).internet(1).private(4).enterprises(1).huawei(2011).huaweiMgmt(5).hwDatacomm(25)

Relationships Between Tables

None.

Description of Single Objects

hwCurrentCfgChgSeqID

OID

Object Name

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.4.1.2011.5.25.191.1.1

hwCurrentCfgChgSeqID

Integer32

Read-only

The value of this object identifies the ID of the current configuration change. The value ranges from 0 to 65535. After the ID of the configuration change reaches the maximum value, the value of the ID starts from 1 again. After the device is restarted, the value of the ID becomes 0.

This object is implemented as defined in the corresponding MIB files.

hwCfgChgSeqIDReveralCount

OID

Object Name

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.4.1.2011.5.25.191.1.2

hwCfgChgSeqIDReveralCount

Integer32

Read-only

The value of this object identifies the alarm ID. The value ranges from 0 to 65535.

This object is implemented as defined in the corresponding MIB files.

hwCfgChgTableMaxItem

OID

Object Name

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.4.1.2011.5.25.191.1.3

hwCfgChgTableMaxItem

Integer32

Read-only

The value of this object identifies the maximum number of entries in hwCfgChgTable. The value ranges from 0 to 65535.

This object is implemented as defined in the corresponding MIB files.

Description of MIB Tables

hwCfgChgTable

This table is used to record configuration changes. In this table, you can find the configuration change based on the specific index.

The index of this table is hwCfgChgSeqID.

OID

Object Name

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.4.1.2011.5.25.191.2.1.1.1

hwCfgChgSeqID

Integer32 (0..65535)

Read-only

The value of this object identifies the configuration change ID. When configuration is changed, the sequence id will plus 1. The value ranges from 0 to 65535.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.191.2.1.1.2

hwCfgChgTime

DateAndTime

Read-only

This object indicates the configuration change time.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.191.2.1.1.3

hwCfgChgTerminalType

INTEGER {snmp(1),telnet(2),netconf(3)}

Read-only

This object indicates the type of the terminal:
  • 1: snmp
  • 2: telnet
  • 3: netconf

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.191.2.1.1.4

hwCfgChgTerminalID

Integer32 (0..2147483647)

Read-only

The value of this object identifies the terminal ID. The value ranges from 0 to 15.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.191.2.1.1.5

hwCfgChgType

INTEGER {create(1),modify(2),delete(3)}

Read-only

This object indicates the configuration change type:

  • 1: create
  • 2: modify
  • 3: delete

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.191.2.1.1.6

hwCfgChgViewName

OctetString

Read-only

This object indicates the name of the view in which the configuration change occurs.

  • For the command operation, the object is the name of the view in which the command is run.
  • For the SNMP operation, the object is the OID of the MIB table or the scalar object.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.191.2.1.1.7

hwCfgChgCmdID

Integer32

Read-only

The value of this object identifies the ID of the configuration change command. For the SNMP operation, the value is 0.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.191.2.1.1.8

hwCfgChgDetailInfo

OctetString

Read-only

This object indicates detailed configuration change information.

  • For the command operation, the object is the command line.
  • For the SNMP operation, the object is the index of the MIB table. When there are multiple indexes, the format of index1.index2.index3 is adopted.

This object is implemented as defined in the corresponding MIB files.

Creation Restriction

No entry can be created in this table.

Modification Restriction

The entries in this table cannot be modified.

Deletion Restriction

The entries in this table cannot be deleted.

Access Restriction

The entries in this table can be read without restraint.

hwCollectTable

This table is used to enable the NMS to send the collecting script to the device to trigger the collection, and then monitor the collection status.

The index of this table is hwCollectIndex.

OID

Object Name

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.4.1.2011.5.25.191.2.2.1.1

hwCollectIndex

Integer32

not-accessible

The value of this object identifies the collection index.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.191.2.2.1.2

hwCollectNetManageId

Integer32

Read-write

The value of this object identifies the NMS ID.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.191.2.2.1.3

hwCollectOperation

INTEGER {begin(1),stop(2)}

Read-write

The value of this object indicates the instruction for the collection operation:
  • 1: begin
  • 2: stop
By default, the value is 2.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.191.2.2.1.4

hwCollectInScriptFile

OCTET STRING (SIZE (1..255))

Read-write

The value of this object indicates the name of the script file. The length of the file name ranges from 1 character to 255 characters.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.191.2.2.1.5

hwCollectInResultFile

OCTET STRING (SIZE (1..255))

Read-write

The value of this object indicates the name of the result file. The length of the file name ranges from 1 character to 255 characters.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.191.2.2.1.6

hwCollectState

INTEGER {idle(1),collecting(2)}

Read-only

The value of this object indicates the collection status:

  • 1: idle
  • 2: collecting

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.191.2.2.1.7

hwCollectRowStatus

RowStatus

Read-create

The value of this object indicates the row status:

  • CreateAndGo

  • Active

  • Destroy

This object is implemented as defined in the corresponding MIB files.

Creation Restriction

  • When entries in this table are created in CreateAndGo mode, the script file name and result file name must be both specified. The paths for the two files must be legal and in full length. What is more, the suffix of the script file name must be ".xml", and the suffix of the result file name must be ".zip"; otherwise, the entry creation fails.

  • This table allows the existence of only one entry. If an entry already exists in the table, the creation of a new entry fails.

Modification Restriction

The entries in this table cannot be modified.

Deletion Restriction

The entries in this table cannot be deleted.

Access Restriction

The entries in this table can be read without restriction.

Description of Alarm Objects

hwCfgChgNotify

OID

Object Name

Bound Variable

Description

Implemented Specifications

1.3.6.1.4.1.2011.5.25.191.3.1

hwCfgChgNotify

  • hwCfgChgSeqID
  • hwCfgChgSeqIDReveralCount
  • hwCfgChgTableMaxItem

This trap is generated when a configuration change occurs on the device within a specified period.

This object is implemented as defined in the corresponding MIB files.

Translation
Download
Updated: 2019-10-17

Document ID: EDOC1000178290

Views: 879544

Downloads: 58

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next