MIB Reference

S7700 and S9700 V200R011C10

This document provides the function overview, relationships between tables, description of single objects, description of MIB tables, and description of alarm objects.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
HUAWEI-NTPV3-MIB

HUAWEI-NTPV3-MIB

Functions Overview

This MIB is mainly used to manage NTP.

Root node:

iso(1).org(3).dod(6).internet(1).private(4).enterprises(1).huawei(2011).huaweiMgmt(5).hwDatacomm(25).hwNtpV3(234).hwNtpV3MibObjects(1).

Relationships Between Tables

None

Description of Single Objects

hwNtpV3ServerIPAdd

OID

Object Name

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.4.1.2011.5.25.234.1.1

hwNtpV3ServerIPAdd

IpAddress

Read-write

Indicates the IP address for an NTP IPv4 server or the first 4 bytes in the MD5 hashed value of the IPv6 address for an NTP IPv6 server.

Set operation on this node will set the unicast server IP address. Get operation on this node will give the system reference clock ID.

This object is implemented as defined in the corresponding MIB files.

hwNtpV3TimeSyncPeriod

OID

Object Name

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.4.1.2011.5.25.234.1.2

hwNtpV3TimeSyncPeriod

Integer32

Read-write

Indicates the interval at which the NTP server will be polled.

NOTE:
The configured interval is applicable only for the current packet.

Currently, the syntax is Unsigned32.

hwNtpV3TimeAfterNTPCal

OID

Object Name

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.4.1.2011.5.25.234.1.3

hwNtpV3TimeAfterNTPCal

DisplayString

Read-only

Indicates the current local time of the system. The unit is Date And Time.

This object is implemented as defined in the corresponding MIB files.

Description of Alarm Objects

This MIB does not contain alarm objects.