Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Default Settings for LDT and LBDT

Default Settings for LDT and LBDT

Table 20-5  Default setting for LDT

Parameter

Default Setting

LDT

Disabled globally and in a VLAN, and enabled on an interface

Action taken after a loop is detected

Shutdown

Interval for sending LDT packets

5s

Interface recovery time

255s

Table 20-6  Default setting for LBDT
Parameter Default Setting

Automatic LBDT

Enable

Manual LBDT

Disabled on an interface and in a VLAN

Action after a loop is detected

Shutdown

Interval for sending LBDT packets

5s

Interface recovery time

3 times the interval for sending detection packets