Configuration Guide - Ethernet Switching

S7700 and S9700 V200R011C10

This document describes the configuration of Ethernet services, including configuring link aggregation, VLANs, Voice VLAN, VLAN mapping, QinQ, GVRP, MAC table, STP/RSTP/MSTP, SEP, and so on.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Example for Configuring LBDT to Detect Loops on the Downstream Network

Example for Configuring LBDT to Detect Loops on the Downstream Network

Networking Requirements

As shown in Figure 20-8, a new department of an enterprise connects to aggregation switch Switch, and this department belongs to VLAN 100. Loops may occur due to incorrect connections or configurations. As a result, communication on the Switch and uplink network may be affected.

It is required that the Switch should detect loops on the new network to prevent the impact of loops on the Switch and connected network.

Figure 20-8  Networking for configuring LBDT to detect loops on the downstream network

Configuration Roadmap

The new department network has only VLAN 100, so configure LBDT on the Switch to detect loops. The configuration roadmap is as follows:

  1. Enable LBDT on the GE1/0/1 of the Switch to detect loops in a specified VLAN so that loops on the downstream network can be detected.
  2. Set LBDT parameters so that the Switch can immediately shut down GE1/0/1 after a loop is detected. This prevents the impact of the loop on the Switch and connected network.
NOTE:

Configure interfaces on other switching interfaces as trunk or hybrid interfaces and configure these interfaces to allow packets from VLANs to pass through to ensure Layer 2 connectivity on the new network and between the new network and the Switch.

Procedure

  1. Enable LBDT on the interface.

    <HUAWEI> system-view
    [HUAWEI] sysname Switch
    [Switch] interface gigabitethernet 1/0/1
    [Switch-GigabitEthernet1/0/1] loopback-detect enable
    [Switch-GigabitEthernet1/0/1] quit

  2. Specify the VLAN ID of LBDT packets.

    [Switch] vlan 100
    [Switch-vlan100] quit
    [Switch] interface gigabitethernet 1/0/1
    [Switch-GigabitEthernet1/0/1] port link-type hybrid
    [Switch-GigabitEthernet1/0/1] port hybrid tagged vlan 100
    [Switch-GigabitEthernet1/0/1] loopback-detect packet vlan 100
    [Switch-GigabitEthernet1/0/1] quit

  3. Configure LBDT parameters.

    # Set the interval for sending LBDT packets.

    [Switch] loopback-detect packet-interval 10

    # Configure an action taken after a loop is detected.

    [Switch] interface gigabitethernet 1/0/1
    [Switch-GigabitEthernet1/0/1] loopback-detect action shutdown
    [Switch-GigabitEthernet1/0/1] quit

  4. Verify the configuration.

    1. Run the display loopback-detect command to check the LBDT configuration.

      [Switch] display loopback-detect                                              
      Loopback-detect sending-packet interval: 10
      
      (A): Auto Loopback-detect                                                                                                           
      -----------------------------------------------------------------                                                                   
      Interface                     RecoverTime  Action     Status                                                                        
      -----------------------------------------------------------------
      GigabitEthernet1/0/1          30           shutdown   NORMAL
      -----------------------------------------------------------------

      The preceding command output shows that the LBDT configuration is successful.

    2. Construct loops on the downstream network and run the display loopback-detect command to check whether GE1/0/1 is shut down.

      [Switch] display loopback-detect 
      Loopback-detect sending-packet interval: 10                                     
                                                                                      
      (A): Auto Loopback-detect                                                                                                           
      -----------------------------------------------------------------                                                                   
      Interface                     RecoverTime  Action     Status                                                                        
      -----------------------------------------------------------------
      GigabitEthernet1/0/1          30           shutdown   SHUTDOWN
      -----------------------------------------------------------------

      The preceding command output shows that GE1/0/1 is shut down.

Configuration Files

Switch configuration file

#
sysname Switch
#
vlan batch 100
#
loopback-detect packet-interval 10
#
interface GigabitEthernet1/0/1
 port link-type hybrid
 port hybrid tagged vlan 100
 loopback-detect packet vlan 100
 loopback-detect enable
#
return