Configuration Guide - Security

S7700 and S9700 V200R011C10

This document describes the configurations of Security, including ACL, reflective ACL, local attack defense, MFF, attack defense, traffic suppression and storm control, ARP security, port security, DHCP snooping, ND snooping, PPPoE+, IPSG, SAVI, URPF, keychain, separating the management plane from the service plane, security risks.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Configuring the Alarm Function for Potential ARP Attacks

Configuring the Alarm Function for Potential ARP Attacks

Context

After rate limiting on ARP packets based on the source IP address is enabled, if the number of ARP packets the device receives per second exceeds the limit, the device discards the excess ARP packets. The device considers the excess ARP packets as potential attacks. The device sends ARP alarms indicating potential attacks to the NMS. To avoid excessive alarms when ARP attacks occur, reduce the alarm quantity by setting a proper interval for sending alarms.

NOTE:

The configuration takes effect only on the alarm for ARP rate limit based on source IP addresses (corresponding to arp speed-limit source-ip). The other ARP alarms are generated at a fixed interval of 5 seconds.

Procedure

  1. Run the system-view command to enter the system view.
  2. Run the arp anti-attack log-trap-timer time command to set the interval for sending ARP alarms.

    The default interval for sending alarms is 0, indicating that the device does not send ARP alarms.