Configuration Guide - Reliability

S9300, S9300E, and S9300X V200R011C10

This document describes the configuration of BFD, DLDP, VRRP, SmartLink, CFM, EFM, Y.1731 and MAC swap loopback to ensure reliability on the device.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
BFD for MPLS LSPs

BFD for MPLS LSPs

A BFD session established on an LSP can quickly detect faults and provide end-to-end protection for the LSP. When a BFD session is associated with a unidirectional LSP, the reverse link can be an IP Link, an LSP, or a TE tunnel.

Both static and dynamic BFD sessions can monitor the connectivity of MPLS LSPs. Dynamic BFD sessions support only dynamic LSPs. Static BFD sessions support static and dynamic LSPs.

To monitor connectivity of an LSP, the ingress and egress nodes periodically send BFD packets to each other. If the ingress or egress node does not receive BFD packets from the other end within the specified period, BFD considers the LSP as Down and sends an LSP Down message to the LSP management module (LSPM).

Application

Figure 2-11  BFD for MPLS LSPs

In Figure 2-11, when a fault occurs on the link between PE1 and P1, PE1 can detect the fault through its interface connected to P1. When a fault occurs on the link between P1 and PE2, PE1 cannot detect the fault through its interface connected to P1. BFD for dynamic LSPs needs to be configured to quickly detect faults.

A dynamic LSP destined for PE2 is set up on PE1. BFD for dynamic LSPs is enabled and a BFD session is set up. Additionally, policies of Virtual Private Network fast reroute (VPN FRR) are configured on PE1, and the protection path between PE1 and PE3 is specified. When a fault occurs on the link between PE1 and P1 or between P1 and PE2, PE1 fast detects the LSP fault and triggers VPN FRR switching. Traffic is then switched to the PE1 -> PE3 -> CE2 path.