No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Configuration Guide - Reliability

S9300, S9300E, and S9300X V200R011C10

This document describes the configuration of BFD, DLDP, VRRP, SmartLink, CFM, EFM, Y.1731 and MAC swap loopback to ensure reliability on the device.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Setting CFM Parameters

Setting CFM Parameters

Context

By adjusting Ethernet CFM parameters, you can better implement end-to-end connectivity fault detection on the Ethernet.

Procedure

  • Setting the RMEP activation time

    1. Run system-view

      The system view is displayed.

    2. Run cfm md md-name

      The MD view is displayed.

    3. Run ma ma-name

      The MA view is displayed.

    4. Run active time time

      The RMEP activation time is configured.

  • Setting the anti-jitter time during alarm restoration

    1. Run system-view

      The system view is displayed.

    2. Run cfm md md-name

      The MD view is displayed.

    3. Run ma ma-name

      The MA view is displayed.

    4. Run alarm finish time time

      The anti-jitter time during alarm restoration is configured.

  • Setting the anti-jitter time during alarm generation

    1. Run system-view

      The system view is displayed.

    2. Run cfm md md-name

      The MD view is displayed.

    3. Run ma ma-name

      The MA view is displayed.

    4. Run alarm occur time time

      The anti-jitter time during alarm generation is configured.