Disk Encryption User Guide

OceanStor V5 Series V500R007

This document is applicable to OceanStor 5110 V5, 5110F V5, 5300 V5, 5300F V5, 5500 V5, 5500F V5, 5600 V5, 5600F V5, 5800 V5, 5800F V5, 6800 V5, 6800F V5, 18500 V5, 18500F V5, 18800 V5, and 18800F V5. It introduces how to install and configure key management servers connected to the storage systems that use self-encrypting disks.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Hardware Deployment

Hardware Deployment

This section describes how to install key management servers, connect their cables, and power on the servers.

Prerequisites

  • The installation positions of the two key management servers have been determined.
  • Cables and tools required for hardware installation have been prepared, including:
    • Serial cable (included in the product package)
    • Power cable (included in the product package)
    • Network cable (not included in the product package)
    • Phillips screwdriver (not included in the product package)
    • (Optional) USB-to-serial cable (not included in the product package)
NOTE:

Prepare the USB-to-serial cable if the maintenance terminal has no serial port.

Procedure

  1. Determine the installation positions.

    The key management servers must be installed on standard 19-inch racks. Determine proper positions on the rack to install the two key management servers. Ensure that there is enough space in front of and behind the servers for cable routing and connection, ventilation, and maintenance.

  2. Wear ESD gloves and ESD wrist straps.
  3. Unpack the key management server.
  4. Install the key management server on the rack.
  5. Use a network cable to connect the eth1 port of the key management server to the management network port of the storage system through a switch.
  6. Insert one end of the power cable to the electric socket at the server back, and insert the other end to the external AC power module.
  7. Press the power switch on the front panel.
  8. Put the baffle plate on the front panel, then insert and turn the key.
  9. Repeat 3 to 8 to install and power on the other key management server.
  10. If the maintenance terminal has no serial port, use the USB-to-serial cable to connect the USB port of the maintenance terminal to the serial port of the key management server.
Translation