Basic Storage Service Configuration Guide for Block

OceanStor V5 Series V500R007

This document is applicable to OceanStor 5110 V5, 5300 V5, 5500 V5, 5600 V5, 5800 V5, 6800 V5, 5300F V5, 5500F V5, 5600F V5, 5800F V5, 6800F V5, 18500 V5, 18800 V5, 18500F V5, and 18800F V5. It describes the basic storage services and explains how to configure and manage them.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Viewing Fibre Channel Port Information

Viewing Fibre Channel Port Information

The following procedure guides you through how to view the information about Fibre Channel ports on a storage device.

Prerequisites

A Fibre Channel interface module has been properly installed on a controller.

Procedure

  1. Log in to DeviceManager.
  2. Choose System.
  3. Click the controller enclosure where the Fibre Channel port resides.
  4. Click to switch to the rear view.
  5. Click the Fibre Channel port whose information you want to view.

    The FC Port dialog box is displayed.

    NOTE:

    GUIs may vary with product versions and models. The actual GUIs prevail.

  6. View the Fibre Channel port information.

    Table 6-3 describes Fibre Channel port parameters.

    Table 6-3 Fibre Channel port parameters

    Parameter

    Description

    Value

    Name

    Name of the Fibre Channel port.

    [Example]

    P0

    Location

    Location of the Fibre Channel port.

    [Example]

    XXX0.A1.P0 or XXX0.B.IOM1.P0

    NOTE:

    The displayed information is consistent with actual product specifications.

    Health Status

    Health status of the Fibre Channel port.

    [Example]

    Normal

    Running Status

    Running status of the Fibre Channel port.

    [Example]

    Link up

    WWPN

    WWPN of the Fibre Channel port.

    [Example]

    20181051720c8a61

    Configured Rate (Gbit/s)

    Configured rate of the Fibre Channel port.

    [Example]

    Autonegotiation

    Working Rate (Gbit/s)

    Data transfer rate of the Fibre Channel port.

    [Example]

    8

    Max. Working Rate (Gbit/s)

    Maximum data transfer rate of the Fibre Channel port.

    [Example]

    8

    Working Mode

    Working mode of the Fibre Channel port.

    [Example]

    FC-AL

    Port Switch

    Switch of the Fibre Channel port. Possible values are Enable and Disable. A port will be disconnected if the port switch is set to Disable.

    [Example]

    Enable

    Host Initiator Quantity

    Number of initiators connected to the port.

    [Example]

    1