Installation Guide

OceanStor 5000, 5000F, 6000, and 6000F V5 Series V500R007

This document is applicable to OceanStor 5110 V5, 5110F V5, 5300 V5, 5300F V5, 5500 V5, 5500F V5, 5600 V5, 5600F V5, 5800 V5, 5800F V5, 6800 V5, and 6800F V5 storage systems. It describes hardware installation of those storage systems for helping you easily and quickly finish the installation.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Connecting Controller Enclosures (Direct Connection)

Connecting Controller Enclosures (Direct Connection)

This section describes direct connection networking between controller enclosures when an OceanStor 5000 V5 or 5000F V5 storage system is configured with two controller enclosures (four controllers).

Direct-Connection Networking (Applicable to OceanStor 5300 V5/5500 V5/5300F V5/5500F V5)

This section describes direct-connection networking between controller enclosures when an OceanStor 5300 V5, 5500 V5, 5300F V5, 5500F V5 storage system is configured with two controller enclosures.

Prerequisites
  • Hardware has been deployed.
  • Optical fiber cables have been prepared.
  • Labels of optical fiber cables have been prepared.
Procedure
  1. Locate the optical fiber cables and attach labels to them.
  2. Connect optical fiber cables to controller enclosure 0. Figure 11-1 shows the direct-connection networking of controller enclosures.

    NOTE:

    When a cable is inserted, the insertion time must exceed two minutes. Otherwise, the system may fail to detect the new cable.

  3. Connect cables to the controller enclosure to be added. For details, see Step 2.
  4. Connect other cables as instructed in Step 3.
  5. After connecting all cables, check whether the direct-connection networking meets your requirements.

    Figure 11-1 shows the direct-connection networking of controller enclosures.

    Figure 11-1 Direct-connection networking of controller enclosures

Direct-Connection Networking (Applicable to OceanStor 5600 V5/5800 V5/5600F V5/5800F V5)

This section describes direct-connection networking between controller enclosures when an OceanStor 5600 V5, 5800 V5, 5600F V5, 5800F V5 storage system is configured with two controller enclosures.

Prerequisites
  • Hardware has been deployed.
  • Optical fiber cables have been prepared.
  • Labels of optical fiber cables have been prepared.
Procedure
  1. Locate the optical fiber cables and attach labels to them.
  2. Connect optical fiber cables to controller enclosure 0. Figure 11-2 shows the direct-connection networking of controller enclosures.

    NOTE:

    When a cable is inserted, the insertion time must exceed two minutes. Otherwise, the system may fail to detect the new cable.

  3. Connect cables to the controller enclosure to be added. For details, see Step 2.
  4. Connect other cables as instructed in Step 3.
  5. After connecting all cables, check whether the direct-connection networking meets your requirements.

    Figure 11-2 shows the direct-connection networking of controller enclosures.

    Figure 11-2 Direct-connection networking of controller enclosures

Translation