No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Installation Guide

OceanStor 5000, 5000F, 6000, and 6000F V5 Series V500R007

This document is applicable to OceanStor 5110 V5, 5110F V5, 5300 V5, 5300F V5, 5500 V5, 5500F V5, 5600 V5, 5600F V5, 5800 V5, 5800F V5, 6800 V5, and 6800F V5 storage systems. It describes hardware installation of those storage systems for helping you easily and quickly finish the installation.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Temperature, Humidity, and Altitude

Temperature, Humidity, and Altitude

Temperature, humidity, and altitude requirements must be met so that storage systems can correctly work or be properly stored.

Table 4-7 lists the temperature, humidity, and altitude requirements of the storage systems.

Table 4-7 Requirements on ambient temperature and humidity

Parameter

Condition

Requirement

Temperature

Operating temperature

  • 5°C to 40°C (41°F to 104°F) when the altitude is between -60 m and +1800 m (-196.85 ft. and +5905.51 ft.)
  • At altitudes between 1800 m and 3000 m (5905.51 ft. and 9842.52 ft.), the allowable temperature drops by 1°C (1.8°F) for every 220 m (721.78 ft.) increase in altitude.

Temperature variation in the operating environment

  • Operating: 20°C/h
  • Storage and transportation: 30°C/h

Non-operating temperature

–40°C to 70°C (–40°F to 158°F)

Storage temperature (during transportation and storage with packages)

–40°C to 70°C (–40°F to 158°F)

Humidity

Humidity

10% RHa to 90% RH

Storage humidity

5% RH to 95% RH

Non-operating humidity

5% RH to 95% RH

Maximum humidity variation

10%/h

Altitude

Operating altitude of disks

–304.8 m to +3048 m (–1000 ft. to +10000 ft.)

Non-operating altitude of disks

–305 m to +12192 m (–1000.66 ft. to +40000 ft.)

a: relative humidity (RH)