Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Enabling SM Notification

Enabling SM Notification

This allows specified-severity alarm and event information to be sent to specified mobile phone numbers, helping engineers troubleshoot faults.

Prerequisites

  • You have logged in to DeviceManager as one of the following administrators who have the operation permission:
    • Super administrator
    • Administrator
  • A GSM modem has been installed on the system or maintenance terminal. The COM port of the GSM modem has been configured to send SMs.
  • A storage system has been configured to send only the alarms and events generated after the SM notification is configured, but not alarms or events generated before the configuration.

Context

The SM notification function is not available to read-only users.

Procedure

  1. Log in to DeviceManager.
  2. Choose Settings > Alarm Settings > SM Notification.
  3. Set a mobile phone number to receive short messages.

    1. Select Enable.
    2. Set a phone number for the SM service center.
      NOTE:

      The phone number must be in the following format: plus sign+country code+11 digit phone number of your local SM service center.

    3. Add the phone number.
      1. Click Add.

        The Add Recipient Information dialog box is displayed.

      2. (For V500R007C20 and earlier) Add the phone number and specify the alarm and event severities.
      3. (For V500R007C30) Specify Recipient Phone Number and Notification Type.
        NOTE:
        • If you select Alarm in Notification Type, you must also specify Alarm Severity, which can be Critical, Major, or Warning.
        • You can enable or disable the notification of specific events. For details, see "Managing Event Notification" in the OceanStor V5 Series V500R007 Administrator Guide.
      4. Click OK.

  4. (Optional) Click Test to test whether the storage system has sent notification.
  5. Click Save.

    The Execution Result dialog box is displayed.