No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Installation Guide

OceanStor 5000, 5000F, 6000, and 6000F V5 Series V500R007

This document is applicable to OceanStor 5110 V5, 5110F V5, 5300 V5, 5300F V5, 5500 V5, 5500F V5, 5600 V5, 5600F V5, 5800 V5, 5800F V5, 6800 V5, and 6800F V5 storage systems. It describes hardware installation of those storage systems for helping you easily and quickly finish the installation.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
(Optional) Installing Interface Modules

(Optional) Installing Interface Modules

If a controller enclosure is not equipped with interface modules, insert interface modules into the interface module slots of the controller enclosure before installing it. If a controller enclosure is equipped with interface modules, skip this procedure.

Prerequisites

The following installation tools are ready:

  • ESD gloves
  • ESD clothes
  • ESD wrist strap

Context

Table 5-1 and Table 5-2 describe the interface modules.

Table 5-1 Interface modules connecting to an application server

Type

Rate (Gbit/s)

Number of Ports

Remarks

8 Gbit/s Fibre Channel interface module (four ports)

8/4/2

4

N/A

GE electrical interface module

1

4

N/A

10GE electrical interface module

10

4

N/A

10 Gbit/s FCoE interface module (two ports)

10

2

5110 V5, 5110F V5, and 5300 V5 do not support this module.

16 Gbit/s Fibre Channel Interface Module

16/8/4/2

8

5600 V5, 5800 V5, 5600F V5, and 5800F V5 do not support this module.

8 Gbit/s Fibre Channel interface module (four ports) (eight ports)

8/4/2

8

N/A

56 Gbit/s IB Interface Module

56 (4 x 14)

2

5110 V5, 5110F V5, and 5300 V5 do not support this module.

SmartIO interface module (8 Gbit/s, 10 Gbit/s, 16 Gbit/s)

The optical module rate (8 Gbit/s, 10 Gbit/s or 16 Gbit/s) prevails.

4

N/A

SmartIO interface module (8 Gbit/s, 10 Gbit/s, 16 Gbit/s, 25 Gbit/s, 32 Gbit/s) (Applicable to V500R007C30)

The optical module rate (8 Gbit/s, 10 Gbit/s, 16 Gbit/s, 25 Gbit/s, 32 Gbit/s) prevails.

4

N/A

40GE interface module (Applicable to V500R007C30)

40

2

5110 V5 and 5110F V5 do not support this module.

100GE interface module (Applicable to V500R007C30)

100

2

5110 V5 and 5110F V5 do not support this module.

NOTE:
  • Adaptive connections can be implemented between 10GE electrical ports and GE electrical ports of the storage system.
  • For the differences between the new SmartIO interface module (8 Gbit/s, 10 Gbit/s, 16 Gbit/s, 25 Gbit/s, and 32 Gbit/s) and the original SmartIO interface module (8 Gbit/s, 10 Gbit/s, and 16 Gbit/s), see "Interface Module" in the Product Description of the corresponding product model.
Table 5-2 Interface modules connecting to a disk enclosure

Type

Rate (Gbit/s)

Number of Ports

Remarks

12 Gbit/s SAS interface module

4 x 12/4 x 6/4 x 3

4

6800 V5 and 6800F V5 do not support this module.

12 Gbit/s SAS sharing interface module

4 x 12/4 x 6/4 x 3

12

Applicable to 6800 V5 and 6800F V5

Interface modules are allocated based on the following rules:

  • As shown in Figure 5-11, controllers of a 2 U controller enclosure are controller A and controller B from top to bottom. Controller A and controller B each have two interface module slots. The slots for interface modules of controller A are A0 and A1, and the slots for interface modules of controller B are B0 and B1. When the storage device requires IP Scale-out, SmartIO interface modules must be installed in A1 and B1 slots.
Figure 5-11 Layout of interface module slots on a 2 U controller enclosure

  • As shown in Figure 5-12, the slots for interface modules of a 3 U controller enclosure are B0, B1, B2, B3, B4, B5, B6, B7, A7, A6, A5, A4, A3, A2, A1, and A0 from left to right. Slots A0 to A7 are for the interface modules of controller A, and slots B0 to B7 are for the interface modules of controller B.
NOTE:

Positions of interface modules:

  • Slots A0 and B0 accommodate back-end ports and only allow 12 Gbit/s SAS expansion modules.
  • A6, A7, B6, and B7 are slots for front-end interface modules and do not support 12 Gbit/s SAS expansion modules.
  • When the storage device requires IP Scale-out, SmartIO interface modules must be installed in A3 and B3 slots.
Figure 5-12 Layout of interface module slots on a 3 U controller enclosure

  • Figure 5-13 shows a 6 U controller enclosure. The slots for interface modules of a 6 U controller enclosure are L0, L1, L2, L3, L4, L5, R5, R4, R3, R2, R1, and R0 from left to right. From the top to bottom, the slots are IOM0 and IOM1.
Figure 5-13 Layout of interface module slots on a 6 U controller enclosure

NOTE:

Positions of interface modules:

  • The first pair of SAS interface modules is installed in slots L5 and R5. The second pair of SAS interface modules is installed in slots L4 and R4.
  • Front-end interface modules are installed in slots L0, L1, L2, R0, R1, and R2. Slots L4 and R4 can be used only when slots of other front-end interface modules are fully configured and SAS interface modules are not installed in slots L4 and R4.
  • When the storage device requires IP Scale-out, SmartIO interface modules must be installed in L3IOM0, R3IOM0, L3IOM1, and R3IOM1 slots.
  • Insert interface modules of the same type into a slot of controller A and the corresponding slot of controller B. Insert interface modules of the same type into a slot of controller C and the corresponding slot of controller D.

    For example, if you insert a SmartIO interface module into slot R2IOM0 of controller A, you must insert a SmartIO interface module into slot L2IOM0 on controller B.

  • Interface modules of the same type must be inserted in sequence.
  • After all the configured interface modules are inserted, insert interface module filler panels into vacant slots.

Procedure

  1. Wear an ESD wrist strap, ESD gloves, and ESD clothes.
  2. Take an interface module out of its ESD bag.
  3. Insert the interface module into a vacant slot, as shown in Figure 5-14, Figure 5-15, and Figure 5-16.

    Figure 5-14 Installing an interface module (2 U controller enclosure)

    Figure 5-15 Installing an interface module (3 U controller enclosure)
    Figure 5-16 Installing an interface module (6 U controller enclosure)

Translation
Download
Updated: 2019-07-11

Document ID: EDOC1000181531

Views: 93495

Downloads: 869

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next