OceanStor 5000, 5000F, 6000, and 6000F V5 Series V500R007

This document is applicable to OceanStor 5110 V5, 5110F V5, 5300 V5, 5300F V5, 5500 V5, 5500F V5, 5600 V5, 5600F V5, 5800 V5, 5800F V5, 6800 V5, and 6800F V5 storage systems. It describes hardware installation of those storage systems for helping you easily and quickly finish the installation.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Switch Networking

Switch Networking

This section describes switch networking among controller enclosures when an OceanStor 5000 V5, 6000 V5, 5000F V5, or 6000F V5 storage system is configured with multiple controller enclosures.

Switch Networking (Applicable to OceanStor 5300 V5/5500 V5/5300F V5/5500F V5)

This section describes switch networking among controller enclosures when an OceanStor 5300 V5, 5500 V5, 5300F V5, 5500F V5 storage system is configured with two or four controller enclosures (four or eight controllers).

Prerequisites
  • Hardware has been deployed.
  • Optical fiber cables have been prepared.
  • Labels of optical fiber cables have been prepared.
Procedure
  1. Locate the optical fiber cables and attach labels to them.
  2. Connect optical fiber cables to controller enclosure 0. Figure 11-5 shows the networking diagram of four controllers, and Figure 11-6 shows the networking diagram of eight controllers.

    NOTE:

    When a cable is inserted, the insertion time must exceed two minutes. Otherwise, the system may fail to detect the new cable.

  3. Connect optical fiber cables to the switches.
  4. Connect another cable to the controller enclosure to be added. For details, see Step 2.
  5. After connecting all cables, check whether the switch connection networking meets your requirements.

    For controller enclosures to which you want to add controllers, compare the controller enclosure SNs and connect cables in ascending order of the SNs. For example, the SNs of three controller enclosures to which you want to add controllers are 210235843710E7000007, 210235843710E7000008, and 210235843710E7000009 respectively. When connecting cables, use the controller enclosure whose SN is 210235843710E7000007 as controller enclosure 1, the controller enclosure whose SN is 210235843710E7000008 as controller enclosure 2, and the controller enclosure whose SN is 210235843710E7000009 as controller enclosure 3.

    • Figure 11-5 shows the networking diagram of four controllers.
    Figure 11-5 Networking diagram of four controllers

    • Figure 11-6 shows the networking diagram of eight controllers.
    Figure 11-6 Networking diagram of eight controllers

Switch Networking (Applicable to OceanStor 5600 V5/5800 V5/5600F V5/5800F V5)

This section describes switch networking among controller enclosures when an OceanStor 5600 V5, 5800 V5, 5600F V5, 5800F V5 storage system is configured with two or four controller enclosures (four or eight controllers).

Prerequisites
  • Hardware has been deployed.
  • Optical fiber cables have been prepared.
  • Labels of optical fiber cables have been prepared.
Procedure
  1. Locate the optical fiber cables and attach labels to them.
  2. Connect optical fiber cables to controller enclosure 0. Figure 11-7 shows the networking diagram of four controllers, and Figure 11-8 shows the networking diagram of eight controllers.

    NOTE:

    When a cable is inserted, the insertion time must exceed two minutes. Otherwise, the system may fail to detect the new cable.

  3. Connect optical fiber cables to the switches.
  4. Connect another cable to the controller enclosure to be added. For details, see Step 2.
  5. After connecting all cables, check whether the switch connection networking meets your requirements.

    For controller enclosures to which you want to add controllers, compare the controller enclosure SNs and connect cables in ascending order of the SNs. For example, the SNs of three controller enclosures to which you want to add controllers are 210235843710E7000007, 210235843710E7000008, and 210235843710E7000009 respectively. When connecting cables, use the controller enclosure whose SN is 210235843710E7000007 as controller enclosure 1, the controller enclosure whose SN is 210235843710E7000008 as controller enclosure 2, and the controller enclosure whose SN is 210235843710E7000009 as controller enclosure 3.

    • Figure 11-7 shows the networking diagram of four controllers.
    Figure 11-7 Networking diagram of four controllers

    • Figure 11-8 shows the networking diagram of eight controllers.
    Figure 11-8 Networking diagram of eight controllers

Switch Networking (Applicable to OceanStor 6800 V5/6800F V5)

This section describes switch networking among controller enclosures when an OceanStor 6800 V5 or 6800F V5 storage system is configured with two controller enclosures (six or eight controllers).

Prerequisites
  • Hardware has been deployed.
  • Optical fiber cables have been prepared.
  • Labels of optical fiber cables have been prepared.
Procedure
  1. Locate the optical fiber cables and attach labels to them.
  2. Connect optical fiber cables to controller enclosure 0. Figure 11-9 shows the networking diagram of six controllers, and Figure 11-10 shows the networking diagram of eight controllers.

    NOTE:

    When a cable is inserted, the insertion time must exceed two minutes. Otherwise, the system may fail to detect the new cable.

  3. Connect optical fiber cables to the switches.
  4. Connect another cable to the controller enclosure to be added. For details, see Step 2.
  5. After connecting all cables, check whether the switch connection networking meets your requirements.

    For controller enclosures to which you want to add controllers, compare the controller enclosure SNs and connect cables in ascending order of the SNs. For example, the SNs of three controller enclosures to which you want to add controllers are 210235843710E7000007, 210235843710E7000008, and 210235843710E7000009 respectively. When connecting cables, use the controller enclosure whose SN is 210235843710E7000007 as controller enclosure 1, the controller enclosure whose SN is 210235843710E7000008 as controller enclosure 2, and the controller enclosure whose SN is 210235843710E7000009 as controller enclosure 3.

    • Figure 11-9 shows the networking diagram of six controllers.
    Figure 11-9 Networking diagram of six controllers

    • Figure 11-10 shows the networking diagram of eight controllers.
    Figure 11-10 Networking diagram of eight controllers

Translation
Download
Updated: 2019-07-11

Document ID: EDOC1000181531

Views: 93521

Downloads: 869

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next