Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
(Optional) Installing Other Software on an Application Server

(Optional) Installing Other Software on an Application Server

To use certain functions, you can choose to install the following software on an application server.

Table 13-1 lists other software running on an application server.

Table 13-1 Other software running on an application server

Software Name

Function

Reference Document

UltraPath

When the storage system is building a redundant physical connection to the application server to increase communication link reliability, you can simplify resource management by installing UltraPath to display the redundant paths as one virtual link.

  • When redundant paths are used between the AIX host and Huawei storage device and no SAN boot operation is required, you can use Huawei UltraPath.
  • When redundant paths are used between the AIX host and Huawei storage device and the SAN boot operation is required, AIX host multipathing software and AIX ODM for MPIO must be installed. For details, see Installing AIX ODM for MPIO in the AIX ODM for MPIO User Guide.

For details about installing UltraPath, refer to the OceanStor UltraPath for Windows User Guide, OceanStor UltraPath for Linux User Guide, OceanStor UltraPath for Solaris User Guide, OceanStor UltraPath for AIX User Guide, or OceanStor UltraPath for vSphere User Guide.

NOTE:
  • To install UltraPath in Linux, run the install.sh script.
  • Go to the Support website to obtain the user guide specific to your product.
  • After the multipathing software is installed, you can run a command to query product models supported by the multipathing software. If XSG1 is displayed in the command output, the multipathing software supports OceanStor V5 series.
NOTE:

When the operating system is Linux whose kernel is 3.8 or later (Oracle Linux 6.5 or later, Red Hat 7.0, CentOS 7.0 or later, or SUSE 12 or later). If you select OceanStor UltraPath as multipathing software, use UltraPath 21.1.RC4 or later.

BCManager eReplication

When value-added features (such as asynchronous remote replication and snapshot) are used, BCManager eReplication must be installed to manage these features on the host and protect data consistency.

For details about installing BCManager eReplication, refer to the OceanStor BCManager eReplication User Guide.

NOTE:

Go to the Support website to obtain the user guide specific to your product.

eService

eService is used for equipment monitoring, alarm reporting, and device inspection.

For details about installing eService, refer to the OceanStor eService User Guide.

NOTE:

Go to the Support website to obtain the user guide specific to your product.

SystemReporter

SystemReporter is used for performance and capacity report analysis.

For details about installing SystemReporter, see the corresponding OceanStor SystemReporter User Guide.

NOTE:
  • Go to the Support website to obtain the user guide specific to your product.
  • The versions of SystemReporter and the storage system must be consistent; otherwise, SystemReporter cannot manage the storage system.

The VMware system has its own multipathing software, NMP. You can directly use this software without configuring it. If you use UltraPath, see your UltraPath document. If you use NMP, the recommended configuration is as follows.

Table 13-2 Recommended configuration for NMP

Number of Existing and Planned Controllers

ALUA Enabled (Y/N)

Storage VM Cluster or Not

Recommended SATP Type

Recommended PSP Type

ESXi 5.0 & 5.0 updated version

≤ 2 controllers

Y

N/A

VMW_SATP_ALUA

VMW_PSP_FIXED

≥ 4 controllers

N

N/A

VMW_SATP_DEFAULT_AA

VMW_PSP_FIXED

ESXi 5.1 & 5.1 updated version

≤ 2 controllers

Y

Y

VMW_SATP_ALUA

VMW_PSP_FIXED

N

VMW_SATP_ALUA

VMW_PSP_FIXED

VMW_SATP_ALUA

VMW_PSP_RR

≥ 4 controllers

N

N/A

VMW_SATP_DEFAULT_AA

VMW_PSP_FIXED

ESXi 5.5 & 5.5 updated & 6.0 & 6.0 updated version

≤ 2 controllers

Y

N/A

VMW_SATP_ALUA

VMW_PSP_FIXED

VMW_SATP_ALUA

VMW_PSP_RR

≥ 4 controllers

N

N/A

VMW_SATP_DEFAULT_AA

VMW_PSP_FIXED

If you use UltraPath, see your UltraPath document. Linux has its own multipathing software called Device Mapper. You are able to directly use this software without configuring it, but the recommended configuration is as follows.

Table 13-3 Recommended configuration for Device Mapper

Number of Existing and Planned Controllers

ALUA Enabled (Y/N)

Load Balancing Enabled (Y/N)

Note

Red Hat 4.6 & 4.6 updated version

≤ 2 controllers

Y

Y

You can set the load balancing mode by entering the following content in the multipath.conf file.

defaults {
user_friendly_names            yes
}
device {
vendor                  "HUAWEI"
product                 "XSG1"
path_grouping_policy         multibus
path_checker             tur
path_selector             "round-robin 0"
dev_loss_tmo           10
}

≥ 4 controllers

N

Y

Red Hat 5.11 & 5.11 updated version

≤ 2 controllers

Y

Y

You can set the load balancing mode by entering the following content in the multipath.conf file.

device {
vendor                  "HUAWEI"
product                 "XSG1"
path_grouping_policy        multibus
getuid_callout            "/sbin/scsi_id -g -u -s /block/%n"
path_checker             tur
path_selector             "round-robin 0"
failback                  immediate
}

≥ 4 controllers

N

Y

Red Hat 6.6 & 6.6 updated & 6.7 & 6.7 updated version

≤ 2 controllers

Y

Y

You can set the load balancing mode by entering the following content in the multipath.conf file.

device {
vendor                  "HUAWEI"
product                 "XSG1"
path_grouping_policy        multibus
getuid_callout            "/lib/udev/scsi_id --whitelisted --device=/dev/%n"
path_checker             tur
path_selector             "round-robin 0"
failback                  immediate
}

≥ 4 controllers

N

Y

Red Hat 7.0 & 7.0 updated & 7.2 & 7.2 updated version

≤ 2 controllers

Y

Y

You can set the load balancing mode by entering the following content in the multipath.conf file.

device {
vendor                  "HUAWEI"
product                     "XSG1"
path_grouping_policy multibus
path_checker              tur
path_selector             "round-robin 0"
failback                    immediate
}

≥ 4 controllers

N

Y

SUSE 11 & 11 updated version

≤ 2 controllers

Y

Y

You can set the load balancing mode by entering the following content in the multipath.conf file.

device {
vendor                  "HUAWEI"
product                 "XSG1"
path_grouping_policy multibus
path_checker            tur
path_selector           "round-robin 0"
failback                immediate
dev_loss_tmo          10
}

≥ 4 controllers

N

Y

SUSE 11 & 11 updated version

≤ 2 controllers

Y

Y

You can set the load balancing mode by entering the following content in the multipath.conf file.

device {
vendor                  "HUAWEI"
product                 "XSG1"
path_grouping_policy multibus
path_checker            tur
path_selector           "round-robin 0"
failback                immediate
dev_loss_tmo          10
}

≥ 4 controllers

N

Y