Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Connecting Management Network Ports to the Network

Connecting Management Network Ports to the Network

Connect management network ports on a controller enclosure to network ports on maintenance terminals through a LAN so that management channels are set up for maintenance terminals to manage and maintain the storage device.

Prerequisites

The required installation tools and materials include:

  • Network cables
  • Cable ties
  • Diagonal pliers

Context

  • Each controller is configured with a management network port and a maintenance network port. In normal cases, the management network port is used to configure and manage a storage device. The maintenance network port is designed for special maintenance in emergency.
  • The management network port and the maintenance terminal can correctly communicate with each other (the management network port and the maintenance terminal reside on the same network segment or reside on different network segments but are connected via a route).

Procedure

  1. Locate the network cables that are used to connect the management network ports (MGMT) on the controller enclosure. See Figure 6-64.

    Do not connect the management network port and maintenance network port to the same switch.

    Figure 6-64 Locating network cables

  2. Connect the network cables to the management network ports, as shown in Figure 6-65, Figure 6-66, and Figure 6-67.

    Figure 6-65 Connecting network cables to management network ports on a 2 U controller enclosure
    NOTE:

    Ensure that the management network ports of the two management modules are connected to the LAN.

    Figure 6-66 Connecting network cables to management network ports on a 3 U controller enclosure
    NOTE:

    Ensure that the management network ports of the two management modules are connected to the LAN.

    Figure 6-67 Connecting network cables to management network ports on a 6 U controller enclosure
    NOTE:
    • Ensure that the management network ports of the two management modules are connected to the LAN.
    • For a 6 U controller enclosure, connect only management network port 0 of the two management modules.

  3. Lay out and bind the network cables.

    NOTE: