Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Expansion Rollback (Applicable to V500R007C10 and Later)

Expansion Rollback (Applicable to V500R007C10 and Later)

If controller expansion fails, restore the storage system to factory settings and expand the controllers again.

Symptom

SmartKit may fail to expand controllers because:

  • The configuration information about controller enclosure (enclosure SN: %s) fails to be modified.
  • The BMC information about controller enclosure (enclosure SN: %s) fails to be synchronized.
  • Controllers for expansion fail.
  • The new controller enclosure (enclosure SN: %s) fails to be added to the cluster.

%s indicates the SN of the enclosure.

  • When handling controller expansion failure, remove management network cables and PCIe cables of storage systems that have not been added to the cluster to isolate controllers.
  • For details about how to use the commands mentioned in this chapter, see OceanStor 5000, 5000F, 6000, and 6000F V5 Series V500R007 Advanced O&M Command Reference.
  • Do not restart the controllers to minimize the impact on cluster services.

Fault Diagnosis

Figure 11-14 Process of handling a controller expansion failure for 5000 and 5000F series storage systems

Figure 11-15 Process of handling a controller expansion failure for 6000 and 6000F series storage systems