This document is applicable to OceanStor 2800 V5. Based on the CLI, this document describes how to use various commands classified by functions and how to set the CLI and manage the storage system through these commands. The document that you browse online matches the latest C version of the product. Click Download to download documents of other C versions.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
overload_ctrl show overload_info

overload_ctrl show overload_info

Function

The overload_ctrl show overload_info command is used to query overloaded objects.

Format

overload_ctrl show overload_info

Parameters

None

Views

Diagnostic view

Usage Guidelines

None

Example

To query overloaded objects.

ibc_os_hs:/diagnose>overload_ctrl show overload_info 
Mgmt timer cycle: 1000 
Obj ID           Coefficient      Last value       Sample value     Current value Max value        Value by ratio Type             Level            Target           InnerLevel       InnerTarget       
0|CPU           50               6                7                6                100              6                0                6                100              4                10                
1|PAGE          80               0                0                0                1000000          0                1                6                5                4                10                
2|REQ           50               0                0                0                100              0                1                6                100              4                10                
3|SGL           50               0                0                0                100              0                1                6                100              4                10                
4|PAGEQUOTA     50               0                0                0                424345           0                1                6                100              4                10                
5|CHUNKQUOTA 50               0                0                0                53542            0                0                6                100              4                10                
6|TRANSACTION 50               0                0                0                100              0                1                6                100              4                10         

System Response

The following table describes the parameter meanings.

Parameter

Meaning

Mgmt timer cycle

Information management cycle.

Obj ID

Overloaded object ID.

Coefficient

Critical damping coefficient.

Last value

Last value.

Sample value

Sample value.

Current value

Current value.

Max value

Maximum value.

Value by ratio

Percentage out of the maximum value.

Type

Type.

Level

Level.

Target

Token change percentage.

InnerLevel

Internal overload level.

InnerTarget

Target of internal overload level adjustment.