Advanced O&M Command Reference

OceanStor 2800 V5 V500R007

This document is applicable to OceanStor 2800 V5. Based on the CLI, this document describes how to use various commands classified by functions and how to set the CLI and manage the storage system through these commands. The document that you browse online matches the latest C version of the product. Click Download to download documents of other C versions.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
change logical_port failover

change logical_port failover

Function

The change logical_port failover command is used to fail over the logical port manually.

Format

change logical_port failover service_type=? controller=?

Parameters

Parameter

Description

Value

service_type

Service type of the logical port.

The value is SAN.

controller

Controller ID.

To obtain the value, run "show controller general".

Views

Developer view

Usage Guidelines

Before performing this operation, determine whether the modification is necessary.

Example

Fail over the SAN logical port of controller 0A.

developer:/>change logical_port failover service_type=SAN controller=0A 
DANGER: You are about to perform port failover. This operation may make the link to be unavailable for a short time. If it is FC port failover, the port that has been failed over will generate a linkdown alarm.  
Suggestion: Perform port failover only in upgrade scenarios. Before performing this operation, ensure the system is in normal status, and do not change the system network during failover. 

Have you read danger alert message carefully?(y/n)Y 
Are you sure you really want to perform the operation?(y/n)Y 
Command executed successfully.

System Response

None