No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Advanced O&M Command Reference

OceanStor 2800 V5 V500R007

This document is applicable to OceanStor 2800 V5. Based on the CLI, this document describes how to use various commands classified by functions and how to set the CLI and manage the storage system through these commands. The document that you browse online matches the latest C version of the product. Click Download to download documents of other C versions.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
drvunf showsfpinfo

drvunf showsfpinfo

Function

The drvunf showsfpinfo command is used to query the optical module on a specific Fibre Channel port.

Format

drvunf showsfpinfo portid

Parameters

Parameter

Description

Value

portid

Port ID.

To obtain the value, run the "drvunf showportinfo" command.For example, 0x110000.

Views

Diagnostic view

Usage Guidelines

None

Example

To query the optical module on port 0 in slot 0 of the Fibre Channel interface module, run the following command.

admin:/diagnose>drvunf showsfpinfo 0x110000 
Vendor name: FINISAR CORP. 
Vendor OUI: 009065 
Serial Num: UQS1ENF 
Date: 20140115 
Bitrate: 14000 
Los: No 
Tx fault: No 
Tx dis: No 
Tx soft-dis: No 
Rx rate : No 
Rx soft-rat: No 
Temperature: 38 ( 0 Y, 70 Y) 
Vcc(mV): 3283 ( 3100 Y, 3500 Y) 
Tx pow(uW): 490 ( 158 Y, 794 Y) 
Tx bias(uA): 7782 ( 2000 Y,11500 Y) 
Rx pow(uW): 514 ( 15 Y, 1000 Y)

System Response

The following table describes the parameter meanings.

Parameter

Meaning

Vendor Name

Vendor name.

Vendor OUI

Vendor ID.

Serial Number

Serial number.

Date

Production data.

Bitrate

Bit rate.

Los

Los signal.

Tx fault

Signal transmission faults.

Tx dis

Digital state of the TX Fault Output Pin.

Tx soft-dis

Digital state of the TX Disable Input Pin.

Rx rate

Read/write bit that allows software disable of laser.

Rx soft-rat

Read/write bit that allows software rate select control.

Temperature

Temperature.

Vcc(mV)

Voltage.

Tx pow(uW)

Transmission power.

Tx bias(uA)

Current.

Rx pow(uW)

Receiving power.

Translation
Download
Updated: 2019-07-11

Document ID: EDOC1000181575

Views: 667929

Downloads: 30

Average rating:
This Document Applies to these Products
Related Version
Related Documents
Share