rephc queryarrayinfo
Function
Example
Query the compatibility information about HyperMetro arrays.
admin:/diagnose>rephc queryarrayinfo Get REPHC array compatible info: arrayid(0). arrayId :0 hcIsCompatible :1 NashcIsCompatible :1 sanhcVersion :1 nashcVersion :257 isSupportSan :1 isSupportNas :1 sanioVersion :196608 nasioVersion :196608 fsioVersion :100 domainIsCompatible :1 domainVersion :1 isSupportSync3dc :1 isSupportLunAlua :1 isSupportAutoRec :1 isSupportOptLock :1 isSupportSlvRecover :1 isSupportIoErrFwd :1 isSupportConfigFwSwitch :1 isSupportArbMode :1 isSupportCgAddNormalPair :1 isSupportDoubleCps :1 isSupportLunExpand :1 isSupportEnterpriseWorm :1 isSupportAtomicCopy :1 isSupportNew2Cps :1 isSupportCrtPause :1 isSupNormUpgrade :1 ioCapVersion :0 isSupportDoubleCps :1 sanAbility :1 note -- 0bit: support disguise lun
System Response
The following table describes the parameter meanings.
Parameter |
Meaning |
---|---|
arrayId | Array ID. |
hcIsComPatible | Whether two arrays are compatible with SAN HyperMetro. |
NashcIsCompatible | Whether two arrays are compatible with NAS HyperMetro. |
sanhcVersion | SAN HyperMetro version. |
nashcVersion | NAS HyperMetro version. |
isSupportSan | Whether SAN HyperMetro is supported. |
isSupportNas | Whether NAS HyperMetro is supported. |
sanioVersion | Block I/O version. |
nasioVersion | Object I/O version. |
fsioVersion | File system I/O version. |
domainIsCompatible | Whether two arrays are compatible with a HyperMetro domain. |
domainVersion | Disk domain version. |
isSupportSync3dc | Whether the HyperMetro solution can be expanded to the DR Star solution. |
isSupportLunAlua | Whether ALUA is supported. |
isSupportAutoRec | Whether automatic recovery is supported when two arrays are powered off concurrently. |
isSupportOptLock | Whether the optimistic lock is supported. |
isSupportSlvRecover | Whether HyperMetro dual secondary arrays support automatic recovery. |
isSupportIoErrFwd | Whether I/O errors can be forwarded to the HyperMetro primary end for processing. |
isSupportConfigFwSwitch | Whether the partition configuration synchronization switch is supported. |
isSupportArbMode | Whether the preferred site mode can be manually set for a vStore pair. |
isSupportCgAddNormalPair | Whether normal members can be added to a HyperMetro consistency group. |
isSupportDoubleCps | Whether dual arbitration is supported. |
isSupportLunExpand | Whether LUN capacity expansion is supported. |
isSupportEnterpriseWorm | Whether enterprise-level WORM is supported. |
isSupportAtomicCopy | Whether atomic copy is supported. |
isSupportNew2Cps | Whether new dual-arbitration is supported. |
isSupportCrtPause | Whether to support the function of suspending a HyperMetro consistency group by default. |
isSupNormUpgrade | Whether an upgrade can be performed without suspending SAN HyperMetro services. |
ioCapVersion | HyperReplication I/O capability version. |
sanAbility | HyperMetro I/O capability version. |
isSupNormUpgradeMv | Whether an upgrade can be performed without suspending intra-array HyperMetro services. |