iod part show all
Function
Example
Display information about CPU partitions in the system.
admin:/diagnose> iod part show all CPU partition cpu information: group_num = 2, partition_num = 18, cores = 144 ============================================== ID GID NUMA Name isIod isKernel CPUNum bitSet - - - ALLCPU - - 144 0 ~ 7 8 ~ 15 16 ~ 23 24 ~ 31 32 ~ 39 40 ~ 47 48 ~ 55 56 ~ 63 64 ~ 71 72 ~ 79 80 ~ 87 88 ~ 95 96 ~ 103 104 ~ 111 112 ~ 119 120 ~ 127 128 ~ 135 136 ~ 143 1 0 0 MGR_P0 N N 1 1....... ........ ........ ........ ........ ........ ........ ........ ........ ........ ........ ........ ........ ........ ........ ........ ........ ........ 2 0 0 MGR_GE N N 1 1....... ........ ........ ........ ........ ........ ........ ........ ........ ........ ........ ........ ........ ........ ........ ........ ........ ........ 3 0 0 FC_P0 N N 4 ........ ........ ........ ....1111 ........ ........ ........ ........ ........ ........ ........ ........ ........ ........ ........ ........ ........ ........ 4 0 0 ISCSI_P0 N N 4 ........ ........ ........ ....1111 ........ ........ ........ ........ ........ ........ ........ ........ ........ ........ ........ ........ ........ ........ 5 0 0 SAS_P0 N N 2 ........ ........ ........ ........ 11...... ........ ........ ........ ........ ........ ........ ........ ........ ........ ........ ........ ........ ........ 6 0 0 IOD_P0 Y Y 27 .1111111 11111111 11111111 1111.... ........ ........ ........ ........ ........ ........ ........ ........ ........ ........ ........ ........ ........ ........ 7 0 0 BDM_P0 Y N 8 ........ ........ ........ ........ ....1111 1111.... ........ ........ ........ ........ ........ ........ ........ ........ ........ ........ ........ ........ 8 0 0 XNET3_P0 Y N 2 ........ ........ ........ ........ ..11.... ........ ........ ........ ........ ........ ........ ........ ........ ........ ........ ........ ........ ........ 9 0 0 XNET2_P0 Y Y 4 ........ ........ ........ ........ ........ ....1111 ........ ........ ........ ........ ........ ........ ........ ........ ........ ........ ........ ........ 10 1 0 FC_P1 N N 4 ........ ........ ........ ........ ........ ........ ........ ........ ........ ....1111 ........ ........ ........ ........ ........ ........ ........ ........ 11 1 0 ISCSI_P1 N N 4 ........ ........ ........ ........ ........ ........ ........ ........ ........ ....1111 ........ ........ ........ ........ ........ ........ ........ ........ 12 1 0 SAS_P1 N N 2 ........ ........ ........ ........ ........ ........ ........ ........ ........ ........ 11...... ........ ........ ........ ........ ........ ........ ........ 13 1 0 IOD_P1 Y Y 27 ........ ........ ........ ........ ........ ........ .1111111 11111111 11111111 1111.... ........ ........ ........ ........ ........ ........ ........ ........ 14 1 0 BDM_P1 Y N 8 ........ ........ ........ ........ ........ ........ ........ ........ ........ ........ ....1111 1111.... ........ ........ ........ ........ ........ ........ 15 1 0 XNET3_P1 Y N 2 ........ ........ ........ ........ ........ ........ ........ ........ ........ ........ ..11.... ........ ........ ........ ........ ........ ........ ........ 16 1 0 XNET2_P1 Y Y 4 ........ ........ ........ ........ ........ ........ ........ ........ ........ ........ ........ ....1111 ........ ........ ........ ........ ........ ........ 17 1 0 MGR_P1 N N 1 ........ ........ ........ ........ ........ ........ 1....... ........ ........ ........ ........ ........ ........ ........ ........ ........ ........ ........ CPU partition thread information: CPU thread partition num = 18(4 iod domain), threads = 143 ============================================== ID Name ThreadNum isIod isKernel threadSet 1 MGR_P0 0 N N 2 MGR_GE 0 N N 3 FC_P0 4 N N 27 28 29 30 4 ISCSI_P0 4 N N 27 28 29 30 5 SAS_P0 2 N N 31 32 6 IOD_P0 27 Y Y 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 7 BDM_P0 8 Y N 35 36 37 38 39 40 41 42 8 XNET3_P0 2 Y N 33 34 9 XNET2_P0 4 Y Y 43 44 45 46 10 FC_P1 4 N N 75 76 77 78 11 ISCSI_P1 4 N N 75 76 77 78 12 SAS_P1 2 N N 79 80 13 IOD_P1 27 Y Y 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 14 BDM_P1 8 Y N 83 84 85 86 87 88 89 90 15 XNET3_P1 2 Y N 81 82 16 XNET2_P1 4 Y Y 91 92 93 94 17 MGR_P1 1 N N 47 Partition to dispatch partition map: ============================================== (null)-->IOD_P1 MGR_P0-->IOD_P0 MGR_GE-->IOD_P0 FC_P0-->IOD_P0 ISCSI_P0-->IOD_P0 SAS_P0-->IOD_P0 IOD_P0-->IOD_P0 BDM_P0-->IOD_P0 XNET3_P0-->IOD_P0 XNET2_P0-->XNET2_P0 FC_P1-->IOD_P1 ISCSI_P1-->IOD_P1 SAS_P1-->IOD_P1 IOD_P1-->IOD_P1 BDM_P1-->IOD_P1 XNET3_P1-->IOD_P1 XNET2_P1-->XNET2_P1 MGR_P1-->IOD_P1 =============================================== CPU ID to dispatch partition map: 0 -> IOD_P0 1 -> IOD_P0 2 -> IOD_P0 3 -> IOD_P0 4 -> IOD_P0 5 -> IOD_P0 6 -> IOD_P0 7 -> IOD_P0 8 -> IOD_P0 9 -> IOD_P0 10 -> IOD_P0 11 -> IOD_P0 12 -> IOD_P0 13 -> IOD_P0 14 -> IOD_P0 15 -> IOD_P0 16 -> IOD_P0 17 -> IOD_P0 18 -> IOD_P0 19 -> IOD_P0 20 -> IOD_P0 21 -> IOD_P0 22 -> IOD_P0 23 -> IOD_P0 24 -> IOD_P0 25 -> IOD_P0 26 -> IOD_P0 27 -> IOD_P0 28 -> IOD_P0 29 -> IOD_P0 30 -> IOD_P0 31 -> IOD_P0 32 -> IOD_P0 33 -> IOD_P0 34 -> IOD_P0 35 -> IOD_P0 36 -> IOD_P0 37 -> IOD_P0 38 -> IOD_P0 39 -> IOD_P0 40 -> IOD_P0 41 -> IOD_P0 42 -> IOD_P0 43 -> IOD_P0 44 -> XNET2_P0 45 -> XNET2_P0 46 -> XNET2_P0 47 -> XNET2_P0 48 -> IOD_P1 49 -> IOD_P1 50 -> IOD_P1 51 -> IOD_P1 52 -> IOD_P1 53 -> IOD_P1 54 -> IOD_P1 55 -> IOD_P1 56 -> IOD_P1 57 -> IOD_P1 58 -> IOD_P1 59 -> IOD_P1 60 -> IOD_P1 61 -> IOD_P1 62 -> IOD_P1 63 -> IOD_P1 64 -> IOD_P1 65 -> IOD_P1 66 -> IOD_P1 67 -> IOD_P1 68 -> IOD_P1 69 -> IOD_P1 70 -> IOD_P1 71 -> IOD_P1 72 -> IOD_P1 73 -> IOD_P1 74 -> IOD_P1 75 -> IOD_P1 76 -> IOD_P1 77 -> IOD_P1 78 -> IOD_P1 79 -> IOD_P1 80 -> IOD_P1 81 -> IOD_P1 82 -> IOD_P1 83 -> IOD_P1 84 -> IOD_P1 85 -> IOD_P1 86 -> IOD_P1 87 -> IOD_P1 88 -> IOD_P1 89 -> IOD_P1 90 -> IOD_P1 91 -> IOD_P1 92 -> XNET2_P1 93 -> XNET2_P1 94 -> XNET2_P1 95 -> XNET2_P1 96 -> IOD_P0 97 -> IOD_P0 98 -> IOD_P0 99 -> IOD_P0 100 -> IOD_P0 101 -> IOD_P0 102 -> IOD_P0 103 -> IOD_P0 104 -> IOD_P0 105 -> IOD_P0 106 -> IOD_P0 107 -> IOD_P0 108 -> IOD_P0 109 -> IOD_P0 110 -> IOD_P0 111 -> IOD_P0 112 -> IOD_P0 113 -> IOD_P0 114 -> IOD_P0 115 -> IOD_P0 116 -> IOD_P0 117 -> IOD_P0 118 -> IOD_P0 119 -> IOD_P0 120 -> IOD_P0 121 -> IOD_P0 122 -> IOD_P0 123 -> IOD_P0 124 -> IOD_P0 125 -> IOD_P0 126 -> IOD_P0 127 -> IOD_P0 128 -> IOD_P0 129 -> IOD_P0 130 -> IOD_P0 131 -> IOD_P0 132 -> IOD_P0 133 -> IOD_P0 134 -> IOD_P0 135 -> IOD_P0 136 -> IOD_P0 137 -> IOD_P0 138 -> IOD_P0 139 -> IOD_P0 140 -> IOD_P0 141 -> IOD_P0 142 -> IOD_P0 143 -> IOD_P0 =============================================== CPU ID to thread ID map: cpuId ->threadId 0 -> 0 1 -> 0 2 -> 1 3 -> 2 4 -> 3 5 -> 4 6 -> 5 7 -> 6 8 -> 7 9 -> 8 10 -> 9 11 -> 10 12 -> 11 13 -> 12 14 -> 13 15 -> 14 16 -> 15 17 -> 16 18 -> 17 19 -> 18 20 -> 19 21 -> 20 22 -> 21 23 -> 22 24 -> 23 25 -> 24 26 -> 25 27 -> 26 28 -> 27 29 -> 28 30 -> 29 31 -> 30 32 -> 31 33 -> 32 34 -> 33 35 -> 34 36 -> 35 37 -> 36 38 -> 37 39 -> 38 40 -> 39 41 -> 40 42 -> 41 43 -> 42 44 -> 43 45 -> 44 46 -> 45 47 -> 46 48 -> 47 49 -> 48 50 -> 49 51 -> 50 52 -> 51 53 -> 52 54 -> 53 55 -> 54 56 -> 55 57 -> 56 58 -> 57 59 -> 58 60 -> 59 61 -> 60 62 -> 61 63 -> 62 64 -> 63 65 -> 64 66 -> 65 67 -> 66 68 -> 67 69 -> 68 70 -> 69 71 -> 70 72 -> 71 73 -> 72 74 -> 73 75 -> 74 76 -> 75 77 -> 76 78 -> 77 79 -> 78 80 -> 79 81 -> 80 82 -> 81 83 -> 82 84 -> 83 85 -> 84 86 -> 85 87 -> 86 88 -> 87 89 -> 88 90 -> 89 91 -> 90 92 -> 91 93 -> 92 94 -> 93 95 -> 94 96 -> 95 97 -> 96 98 -> 97 99 -> 98 100 -> 99 101 -> 100 102 -> 101 103 -> 102 104 -> 103 105 -> 104 106 -> 105 107 -> 106 108 -> 107 109 -> 108 110 -> 109 111 -> 110 112 -> 111 113 -> 112 114 -> 113 115 -> 114 116 -> 115 117 -> 116 118 -> 117 119 -> 118 120 -> 119 121 -> 120 122 -> 121 123 -> 122 124 -> 123 125 -> 124 126 -> 125 127 -> 126 128 -> 127 129 -> 128 130 -> 129 131 -> 130 132 -> 131 133 -> 132 134 -> 133 135 -> 134 136 -> 135 137 -> 136 138 -> 137 139 -> 138 140 -> 139 141 -> 140 142 -> 141 143 -> 142
System Response
The following table describes the parameter meanings.
Parameter |
Meaning |
---|---|
CPU partition cpu information: | CPU bitmap information of a CPU partition. |
ID | Partition ID. |
GID | Partition group ID. |
NUMA | NUMA ID. |
Name | Partition name. |
isIod | Whether it is an IOD partition. |
isKernel | Whether it is a kernel partition. |
CPUNum | Number of CPU cores in the partition. |
bitSet | Bitmap information. |
CPU partition thread information: | Thread information of a CPU partition. |
ThreadNum | Thread data of the partition. |
threadSet | Thread list of the partition. |
Partition to dispatch partition map: | Dispatch mapping between partitions. |
CPU ID to dispatch partition map: | Mapping between CPU cores and partitions. |
CPU ID to thread ID map: | Mapping between CPU cores and thread IDs. |