drvunf showsfpinfo
Function
Parameters
Parameter |
Description |
Value |
---|---|---|
portid | Port ID. | To obtain the value, run the "drvunf showportinfo" command.For example, 0x110000. |
Example
To query the optical module on port 0 in slot 0 of the Fibre Channel interface module, run the following command.
admin:/diagnose>drvunf showsfpinfo 0x110000 Vendor name: FINISAR CORP. Vendor OUI: 009065 Serial Num: UQS1ENF Date: 20140115 Bitrate: 14000 Los: No Tx fault: No Tx dis: No Tx soft-dis: No Rx rate : No Rx soft-rat: No Temperature: 38 ( 0 Y, 70 Y) Vcc(mV): 3283 ( 3100 Y, 3500 Y) Tx pow(uW): 490 ( 158 Y, 794 Y) Tx bias(uA): 7782 ( 2000 Y,11500 Y) Rx pow(uW): 514 ( 15 Y, 1000 Y)
System Response
The following table describes the parameter meanings.
Parameter |
Meaning |
---|---|
Vendor Name | Vendor name. |
Vendor OUI | Vendor ID. |
Serial Number | Serial number. |
Date | Production data. |
Bitrate | Bit rate. |
Los | LOS signal. |
Tx fault | Signal transmission faults. |
Tx dis | Digital state of the TX Fault Output Pin. |
Tx soft-dis | Digital state of the TX Disable Input Pin. |
Rx rate | Read/write bit that allows software disable of laser. |
Rx soft-rat | Read/write bit that allows software rate select control. |
Temperature | Temperature. |
Vcc(mV) | Voltage. |
Tx pow(uW) | Transmission power. |
Tx bias(uA) | Current. |
Rx pow(uW) | Receiving power. |