change loopback test
Parameters
Parameter |
Description |
Value |
---|---|---|
mode=? | Port test mode. | The value can be "inner", "outer" or "stop", where:
|
type=? | Type. | The value can be "port" or "disk", where:
|
port_type=? | Port type. | The value can be "ETH", "FC", "SAS", "COM" or "FCoE", where:
|
id=? | Port ID. |
|
controller_id=? | Controller ID. | The value can be obtained by running the "show controller general" command. |
time=? | Test duration. | The recommended value ranges from 50 to 120, unit is second. |
Example
Perform an internal loopback test for port "0" of the network adapter in slot "A3" on controller B and set the test duration to "60" seconds.
developer:/>change loopback test mode=inner type=port port_type=ETH id=ENG0.A3.P0 controller_id=0B time=60 DANGER: You are about to perform a loopback diagnosis test on the specified port. This operation interrupts all services running on the module where the port resides. Suggestion: 1. Stop services related to the interface module. 2. Run the "change alarm_mask alarm_id_list=link-related" command to mask alarms. 3. Remove the cables of the module. Have you read danger alert message carefully?(y/n)y Are you sure you really want to perform the operation?(y/n)y Command executed successfully.