No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Advanced O&M Command Reference

OceanStor 2800 V5 V500R007

This document is applicable to OceanStor 2800 V5. Based on the CLI, this document describes how to use various commands classified by functions and how to set the CLI and manage the storage system through these commands. The document that you browse online matches the latest C version of the product. Click Download to download documents of other C versions.

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
sddebug show diskrenostate

sddebug show diskrenostate

Function

The sddebug show diskrenostate command is used to query the refurbishment status of a specified disk.

Format

sddebug show diskrenostate sdid=?

sddebug show diskrenostate sdid=? usermode

Parameters

Parameter

Description

Value

sdid=? Physical ID of a disk.

To obtain the value, run the "sddebug show disk -app_data" or "sddebug show disk" command.

usermode
  • When this parameter is mandatory, the current command can be used only in the user mode.
  • When this parameter is optional, the current command can be used in both the user mode and kernel mode.

The value is "-app_data", indicating that the command is executed in the user mode.

Views

Diagnostic view

Usage Guidelines

  • Run the "sddebug show diskrenostate sdid=? -app_data" command to query the refurbishment status of a specified disk in the user mode.
  • Run the "sddebug show diskrenostate sdid=?" command to query the refurbishment status of a specified disk in the kernel mode.
  • Run the "sddebug show diskrenostate" command in the user mode when the system supports both the kernel and user modes.

Example

  • Query the refurbishment status of the disk whose physical ID is "64".

    admin:/diagnose> sddebug show diskrenostate sdid=64 -app_data
    Disk 64 renovation state 2 .
  • Query the refurbishment status of the disk whose physical ID is "70".

    admin:/diagnose>sddebug show diskrenostate sdid=70
    Disk 70 renovation state 2 .

System Response

None

Translation
Download
Updated: 2020-01-17

Document ID: EDOC1000181575

Views: 725061

Downloads: 32

Average rating: