sys showfrustatus
Function
The sys showfrustatus command is used to view the status of field replaceable units (FRUs).
Format
sys showfrustatus
Parameters
None
Views
Diagnostic view
Usage Guidelines
None
Example
View the status of FRUs.
admin:/diagnose>sys showfrustatus
Fru state is 0x0 .
cacheState : back
engineVaultState : normal
hightempState : recover one
singleNodeWriteThrough: close
node id type status
------- -------------- ------
0 BBU normal
0 SSD normal
0 boardTempState recover one
1 BBU normal
1 SSD normal
1 boardTempState recover one
admin:/diagnose>
System Response
The following table describes the parameter meanings.
Parameter |
Meaning |
---|---|
Fru state is |
Current FRU status. |
cacheState |
Write-back/write-through status of cache. |
engineVaultState |
Coffer disk status. |
hightempState |
High temperature status. |
singleNodeWriteThrough |
Switch of single-node write through. |
node id |
Node ID. |
type |
FRU type. |
status |
Status. |