Command Reference

OceanStor 18000 and 18000F V5 Series V500R007

This document is applicable to OceanStor 18500 V5, 18800 V5, 18500F V5, and 18800F V5. Based on the CLI provided by DeviceManager, this document describes how to use various commands classified by functions and how to set the CLI and manage the storage system through these commands. The document that you browse online matches the latest C version of the product. Click Download to download documents of other C versions.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
add failover_group fc_port

add failover_group fc_port

Function

The add failover_group fc_port command is used to add FC ports to a customized SAN failover group.

Format

add failover_group fc_port failover_group_id=? fc_port_list=?

Parameters

Parameter

Description

Value

failover_group_id=?

ID of a failover group.

  • The value is an integer between 1 and 1024.
  • To obtain the value, run the "show failover_group general" command without parameters.

fc_port_list=?

List of FC ports.

  • To obtain the value, run the "show port general physical_type=FC" command.
  • When multiple FC ports are entered, separate the port names from each other using commas (,).

Level

Administrator

Usage Guidelines

  • The "failover_group_id" supports only the ID of a customized failover group.
  • The "fc_port_list" supports one or more FC port names.

Example

  • Add an FC port to a customized failover group.
    admin:/>add failover_group fc_port failover_group_id=1 fc_port_list=CTE0.A1.P1 
    Add FC port CTE0.A1.P1 to failover group successfully.
  • Add FC ports to a customized failover group.
    admin:/>add failover_group fc_port failover_group_id=1 fc_port_list=CTE0.A1.P1,CTE0.A1.P2 
    Add FC port CTE0.A1.P1 to failover group successfully. 
    Add FC port CTE0.A1.P2 to failover group successfully.
  • Add FC ports to a customized failover group.
    admin:/>add failover_group fc_port failover_group_id=1 fc_port_list=CTE0.A1.P1,CTE0.B1.P2 
    Add FC port CTE0.A1.P1 to failover group successfully. 
    Error: The object does not exist. 
    Add FC port CTE0.B1.P2 to failover group failed.