Command Reference

OceanStor 18000 and 18000F V5 Series V500R007

This document is applicable to OceanStor 18500 V5, 18800 V5, 18500F V5, and 18800F V5. Based on the CLI provided by the DeviceManager, this document describes how to use variouscommands classified by functions and how to set the CLI and manage the storage system throughthese commands. The document that you browse online matches the latest C version of the product. Click Download to download documents of other C versions.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
change notification sms_function

change notification sms_function

Function

The change notification sms_function command is used to enable or disable the short message service (SMS) for alarms or events.

Format

change notification sms_function enabled=?

Parameters

Parameter

Description

Value

enabled=?

Switch of the SMS function.

The value can be "yes" or "no", where:

  • "yes": The SMS function is enabled.
  • "no": The SMS function is disabled.

The default value is "yes".

Level

Super administrator

Usage Guidelines

None

Example

Disable the SMS function.

admin:/>change notification sms_function enabled=no  
CAUTION: You are about to disable the SMS function. 
After the SMS function is disabled, an error message will be returned when SMS configurations are queried, and the SMS configurations cannot be viewed on the management page. 
Suggestion: Before performing this operation, ensure that you want to disable the SMS function. 
Do you wish to continue?(y/n)y 
Command executed successfully. 
admin:/>

System Response

None