Command Reference

OceanStor 18000 and 18000F V5 Series V500R007

This document is applicable to OceanStor 18500 V5, 18800 V5, 18500F V5, and 18800F V5 storage systems. It describes hardware installation of those storage systems for helping you easily and quickly finish the installation.

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
show expansion_module

show expansion_module

Function

The show expansion_module command is used to query details on expansion modules. Run this command if you need to query an expansion module's type, status and electronic label.

Format

show expansion_module [ expansion_module_id=? ]

Parameters

Parameter

Description

Value

expansion_module_id=? ID of an expansion module.

To obtain the value, run "show expansion_module" without parameters.

Level

Guest

Usage Guidelines

  • To query details on all expansion modules, run show expansion_module.
  • To query details on a specific expansion module, run show expansion_module expansion_module_id=?.

Example

  • Query details on all expansion modules. The command output varies depending on a specific product.

    admin:/>show expansion_module
     
    ID Health Status Running Status Type Voltage(V)
    -------- ------------- -------------- ---- ----------
    DAE000.A Normal Running SAS 3.3
    DAE000.B Normal Running SAS 3.3
  • Query details on the expansion module whose ID is "DAE000.A". The ID and output vary depending on a specific product.

    admin:/>show expansion_module expansion_module_id=DAE000.A
     
    ID : DAE000.A
    Health Status : Normal
    Running Status : Running
    Type : SAS
    Logic Version : 130T01
    PCB Version : STL1DESA VER.B
    SES Version : 10.00T43
    Voltage(V) : 3.3
    Electronic Label : [Board Properties]
    BoardType=STL1DESA
    BarCode=02G258D0C5000610
    Item=0302G258
    Description=PANGEA Hardware Platform,
    STL1DESA,Disk Enclosure Cascading Board,1*1
    Manufactured=2012-05-30
    VendorName=Huawei
    IssueNumber=
    CLEICode=
    BOM=

System Response

The following table describes the parameter meanings.

Parameter

Meaning

Electronic Label

Electronic label of the expansion module.

Type

Type of the expansion module.

Logic Version

Logical version of the expansion module.

Voltage(V)

Voltage of the expansion module (V).

SES Version

SES version of the of the expansion module.

PCB Version

PCB version of the expansion module.

ID

ID of the expansion module.

Running Status

Running status of the expansion module.

Health Status

Health status of the expansion module.