Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
show vlan general

show vlan general

Function

The show vlan general command is used to check existing VLANs and their properties.

Format

show vlan general [ name=? ]

show vlan general [ object_type=? object_id=? ]

Parameters

Parameter

Description

Value

name=? VLAN name.

To obtain the value, run the "show vlan general" command.

object_type=? Type of the object associated with a VLAN.

To obtain the value, run the "show vlan general" command.

object_id=? ID of the object associated with a VLAN.

To obtain the value, run the "show failover_group general" command.

Level

Guest

Usage Guidelines

None

Example

  • Check the properties of all VLANs.

    admin:/>show vlan general
    Name Running Status VLAN ID MTU Port Type Port ID 
    ------------ -------------- ------- ---- ---------- --------- 
    ENG0.A2.P0.2 Link Down 2 1500 ETH ENG0.A2.P0 
    ENG0.A2.P1.1 Link Down 1 1500 ETH ENG0.A2.P1
  • Check the properties of a specific VLAN.

    admin:/>show vlan general name=ENG0.A2.P1.1
    Name : ENG0.A2.P1.1 
    Running Status : Link Down 
    VLAN ID : 1 
    MTU : 1500 
    Port Type : ETH 
    Port ID : ENG0.A2.P1
  • Check objects associated with a VLAN.

    admin:/>show vlan general object_type=failovergroup object_id=0
    Command executed successfully.

System Response

The following table describes the parameter meanings.

Parameter

Meaning

Name

VLAN name.

Running Status

Running status of the VLAN.

VLAN ID

VLAN ID.

MTU

MTU of the VLAN.

Port Type

Type of the VLAN port.

Port ID

ID of the port created by the VLAN.