Command Reference

OceanStor 18000 and 18000F V5 Series V500R007

This document is applicable to OceanStor 18500 V5, 18800 V5, 18500F V5, and 18800F V5. Based on the CLI provided by DeviceManager, this document describes how to use various commands classified by functions and how to set the CLI and manage the storage system through these commands. The document that you browse online matches the latest C version of the product. Click Download to download documents of other C versions.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
change smis configuration

change smis configuration

Function

The change smis configuration command is used to modify the configurations of the SMIS service.

Format

change smis configuration { enable_sslv3=? | enable_tlsv1=? | enable_http_port=? }

Parameters

Parameter

Description

Value

enable_sslv3=?

Status of the SSLv3.0 protocol.

The value can be "yes" or "no", where:

  • "yes": The SSLv3.0 protocol is enabled.
  • "no": The SSLv3.0 protocol is disabled.

enable_tlsv1=?

Status of the TLSv1.0 protocol.

The value can be "yes" or "no", where:

  • "yes": The TLSv1.0 protocol is enabled.
  • "no": The TLSv1.0 protocol is disabled.

enable_http_port=?

Status of the HTTP Port.

The value can be "yes" or "no", where:

  • "yes": The HTTP Port is enabled.
  • "no": The HTTP Port is disabled.

Level

Super administrator

Usage Guidelines

This command cannot be executed on the CLI to which you log in using the controller's management IP address. Before running this command, log in to the CLI using the SVP's management IP address. You need to restart the SMIS service to make the configuration changes take effect.

Example

  • Enable the SSLv3.0 protocol.
    admin:/>change smis configuration enable_sslv3=yes 
    WARNING: You are about to enable the SSLv3.0 protocol.This operation will allow unsecure access that is initiated through SSLv3.0, and user information and data may be intercepted. After this command is executed, SMI-S service must be restarted. 
    Suggestion: Before performing this operation, confirm with the customer that this operation is necessary. 
    Have you read warning message carefully?(y/n)y 
    Are you sure you really want to perform the operation?(y/n)y 
    Command executed successfully.
  • Enable the TLSv1.0 protocol.
    admin:/>change smis configuration enable_tlsv1=yes 
    WARNING: You are about to enable the TLSv1.0 protocol.This operation will allow unsecure access that is initiated through TLSv1.0 , and user information and data may be intercepted. After this command is executed, SMI-S service must be restarted. 
    Suggestion: Before performing this operation, confirm with the customer that this operation is necessary. 
    Have you read warning message carefully?(y/n)y 
    Are you sure you really want to perform the operation?(y/n)y 
    Command executed successfully.
  • Enable the HTTP Port.
    admin:/>change smis configuration enable_http_port=yes 
    WARNING: You are about to enable the HTTP protocol.This operation will allow unsecure access that is initiated through HTTP, and user information and data may be intercepted. After this command is executed, SMI-S service must be restarted. 
    Suggestion: Before performing this operation, confirm with the customer that this operation is necessary. 
    Have you read warning message carefully?(y/n)y 
    Are you sure you really want to perform the operation?(y/n)y 
    Command executed successfully.

System Response

None