No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade
Command Reference
OceanStor 18000 and 18000F V5 Series V500R007

This document is applicable to OceanStor 18500 V5, 18800 V5, 18500F V5, and 18800F V5 storage systems. It describes hardware installation of those storage systems for helping you easily and quickly finish the installation.

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
test domain ad

test domain ad

Function

The test domain ad command is used to test the connectivity of an AD domain server.

Format

test domain ad [ fqdn=? ] [ controller=? ]

Parameters

Parameter

Description

Value

fqdn=? Domain name of the AD domain server.

The value is a character string that consists of 1 to 127 characters.

controller Controller ID.

The value format can be "XA", "XB", "XC" and "XD", where the value of X can be an integer ranging from 0 to 3. To obtain the value, run the show controller general command.

Level

Guest

Usage Guidelines

None

Example

Test the connectivity of the AD domain server whose domain name is "auth2k8.com".

admin:/>test domain ad fqdn=auth2k8.com controller=0A
Command executed successfully.

System Response

None

Translation
Download
Updated: 2020-03-19

Document ID: EDOC1000181601

Views: 406269

Downloads: 56

Average rating:
This Document Applies to these Products

Related Version

Related Documents

Share
Previous Next