Command Reference

OceanStor 18000 and 18000F V5 Series V500R007

This document is applicable to OceanStor 18500 V5, 18800 V5, 18500F V5, and 18800F V5. Based on the CLI provided by the DeviceManager, this document describes how to use variouscommands classified by functions and how to set the CLI and manage the storage system throughthese commands. The document that you browse online matches the latest C version of the product. Click Download to download documents of other C versions.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
show remote_device elink

show remote_device elink

Function

The show remote_device elink command is used to query the information about the heterogeneous links connected to a storage system.

Format

show remote_device elink [ link_type=? ] [ link_id=? ] [ remote_device_id=? ]

Parameters

Parameter

Description

Value

remote_device_id=?

ID of a remote device.

Run the "show remote_device general" command to obtain the value.

link_type=?

Link type.

Values:

  • FC: A remote device is connected to a local device by Fibre Channel links.
  • iSCSI: A remote device is connected to a local device by iSCSI links.

link_id=?

Link ID.

Run the "show remote_device elink" command without parameters to obtain the value.

Level

Guest

Usage Guidelines

  • The link_id parameter can be set only when the link_type is set.
  • The following parameters or parameter sets are mutually exclusive: link_id and remote_device_id.
  • Run the show remote_device elink command to query the information about all links connected to the storage system.
  • Run the show remote_device elink link_type= link_id= command to query the information about a specified link.
  • Run the show remote_device elink remote_device_id= command to query the information about links on a specified remote device.

Example

Query the information about heterogeneous links whose type is Fibre Channel and whose ID is 514.

admin:/>show remote_device elink link_type=FC remote_device_id=514 
ID Health Status Running Status Local Controller Remote Device Type  
--------- ------------- -------------- ---------------- ----------  
268435456 Normal Link Up 0A Heterogeneity 
268435457 Normal Link Up 0B Heterogeneity 
268435458 Normal Link Up 0A Heterogeneity 
268435459 Normal Link Up 0B Heterogeneity 
In Remote Device Remote Device ID Remote Device WWN Remote Controller  
------------ ---------------- ----------------- -----------------  
Yes 514 a1003300 --  
Yes 514 a1003300 --  
Yes 514 a1003300 --  
Yes 514 a1003300 --  

System Response

Parameter

Meaning

ID

ID of the heterogeneous link.

Health Status

Health state of the heterogeneous link.

Running Status

Running state of the heterogeneous link.

Local Controller

ID of local controller.

Remote Device Type

Type of remote device.

In Remote Device

Whether the remote device is connected to the system.

Remote Device ID

ID of remote device.

Remote Device WWN

World wild name of remote device.

Remote Controller

ID of remote controller.

Translation