No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Command Reference

OceanStor 18000 and 18000F V5 Series V500R007

This document is applicable to OceanStor 18500 V5, 18800 V5, 18500F V5, and 18800F V5 storage systems. It describes hardware installation of those storage systems for helping you easily and quickly finish the installation.

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
show bbu general

show bbu general

Function

The show bbu general command is used to query details on BBUs. Run this command if you need to query the ID, status and voltage of the controller where the BBU resides.

Format

show bbu general [ bbu_id=? ]

Parameters

Parameter

Description

Value

bbu_id=? ID of a BBU.

To obtain the value, run "show bbu general" without parameters.

Level

Guest

Usage Guidelines

None

Example

  • Query details on all BBUs. The command output varies depending on a specific product.

    admin:/>show bbu general
     
    ID Health Status Running Status Current Voltage(V) Number of Discharges
    ------- ------------- -------------- ------------------ --------------------
    ENG0.A0 Normal Online 11.7 27
    ENG0.A1 Normal Online 11.7 7
    ENG0.B0 Normal Online 11.7 27
    ENG0.B1 Normal Online 11.7 7
  • Query details on the BBU whose ID is "ENG0.A0". The ID and output vary depending on a specific product.

    admin:/>show bbu general bbu_id=ENG0.A0
     
    ID : ENG0.A0
    Health Status : Normal
    Running Status : Online
    Current Voltage(V) : 11.7
    Number of Discharges : 27
    Firmware Version : 1.17T18
    Delivered On : 2012-4-29
    Owning Controller : 0A
    Electronic Label : [Board Properties]
    BoardType=STLZ01PWRA
    BarCode=210235G404Z0C5000218
    Item=0235G404
    Description=PANGEA,STLZ01PWRA,Battery Backup Unit
    Manufactured=2012-05-19
    VendorName=Huawei
    IssueNumber=00
    CLEICode=
    BOM=

System Response

The following table describes the parameter meanings.

Parameter

Meaning

ID

BBU ID.

Health Status

Health status of a BBU.

Running Status

Running status of a BBU.

Current Voltage(V)

Current voltage of the BBU (V).

Number Of Discharges

Times of BBU discharge.

Firmware Version

Firmware version of the BBU.

Delivered On

Delivery time of the BBU.

Owning Controller

Owning controller of the BBU.

Electronic Label

Electronic label of the BBU.

Translation
Download
Updated: 2020-01-17

Document ID: EDOC1000181601

Views: 378501

Downloads: 49

Average rating:
This Document Applies to these Products

Related Version

Related Documents

Share