Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
poweroff interface_module

poweroff interface_module

Function

The poweroff interface_module command is used to power off a specific interface module.

Format

poweroff interface_module interface_module_id=?

Parameters

Parameter

Description

Value

interface_module_id=? ID of an interface module.

To obtain the value, run "show interface_module" without parameter.

Level

Administrator

Usage Guidelines

Before you perform this operation, ensure that the services of all ports on the interface module are stopped.

Example

To power off the interface module whose ID is CTE0.SMM0, run the following command. The ID and output vary depending on a specific product. To ensure that the interface module can carry services, you need to power on it again.

admin:/>poweroff interface_module interface_module_id=CTE0.SMM0
DANGER: You are about to power off the interface module. 
This operation will cause that the services of all ports on the interface module are interrupted. 
Suggestion: Before you perform this operation, ensure that the services of all ports on the interface module are stopped. To ensure that the interface module can carry services, you need to power on it again.
Have you read danger alert message carefully?(y/n)Y
Are you sure you really want to perform the operation?(y/n)Y
Command executed successfully.

System Response

None