Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
add failover_group eth_port

add failover_group eth_port

Function

The add failover_group eth_port command is used to add Ethernet ports to a customized failover group.

Format

add failover_group eth_port failover_group_id=? eth_port_list=?

Parameters

Parameter

Description

Value

failover_group_id=? ID of a failover group.
  • The value is an integer between 1 and 1024.
  • To obtain the value, run the "show failover_group general" command without parameters.
eth_port_list=? List of Ethernet ports.
  • To obtain the value, run the "show port general physical_type=ETH logic_type=Host_Port" command.
  • When multiple Ethernet ports are entered, separate the port names from each other using commas (,).

Level

Administrator

Usage Guidelines

  • The "failover_group_id" supports only the ID of a customized failover group.
  • The "eth_port_list" supports one or more Ethernet port names.

Example

  • Add an Ethernet port to a customized failover group.

    admin:/>add failover_group eth_port failover_group_id=1 eth_port_list=CTEO.A1.P1
    Add ETH port CTE0.A1.P1 to failover group successfully.
  • Add Ethernet ports to a customized failover group.

    admin:/>add failover_group eth_port failover_group_id=1 eth_port_list=CTE0.A1.P1,CTE0.A1.P2
    Add ETH port CTE0.A1.P1 to failover group successfully.
    Add ETH port CTE0.A1.P2 to failover group successfully.
  • Add Ethernet ports to a customized failover group.

    admin:/>add failover_group eth_port failover_group_id=1 eth_port_list=CTE0.A1.P1,CTE0.B1.P2
    Add ETH port CTE0.A1.P1 to failover group successfully.
    Error: The object does not exist.
    Add ETH port CTE0.B1.P2 to failover group failed. 

System Response

None