Advanced O&M Command Reference

OceanStor 18000 and 18000F V5 Series V500R007

This document is applicable to OceanStor 18500 V5, 18800 V5, 18500F V5, and 18800F V5. Based on the CLI, this document describes how to use various commands classified by functionsand how to set the CLI and manage the storage system through these commands.

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
change root_cause_alarm rule

change root_cause_alarm rule

Function

The change root_cause_alarm rule command is used to set parameters in the root cause alarm table, including whether a rule takes effect, the time that the child alarm waits for the parent alarm when the rule takes effect, and time that the child alarm waits before it is recovered.

Format

change root_cause_alarm rule rule_id=? { delay_time=? | recover_time=? }

change root_cause_alarm rule rule_id=? switch=?

Parameters

Parameter

Description

Value

rule_id=? ID of a rule in the root cause alarm table.

The value must be an integer from 1 to 400.

switch=? Switch of making a rule take effect.

The value can be "on" or "off", where:

  • "on": The rule takes effect.
  • "off": The rule does not take effect.
delay_time=? Timeout period that a child alarm can wait for a system to receive its parent alarm. If a child alarm is received by the system but its parent alarm is not received within this period, the child alarm will be reported. The unit is second.

The value can be "60", "120", "180", "240", "300", "360", "420", "900", or "1800".

recover_time=? Timeout period that a child alarm can wait for a system to receive its recovery alarm. If a child alarm is suppressed and all its parent alarms are recovered but the recovery alarm of this child alarm is not received by the system within this timeout period, the child alarm will be reported. The unit is second.

The value can be "60", "120", "180", "240", "300", "360", "420", "900", or "1800".

Views

Developer view

Usage Guidelines

None

Example

Change the latency of rule 1 in the root cause alarm table.

developer:>change root_cause_alarm rule rule_id=1 delay_time=300
Command executed successfully.

System Response

None