Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
switch

switch

Function

The switch command is used to switch serial ports. You can switch to the serial ports of the management board BMC, control board BMC, and control board OS.

Format

switch <desuart>

Parameters

Parameter

Description

Value

desuart Destination serial port.

x86 system: 3 U devices: 1. In automatic mode, the value is a or b, where:

  • a: switches to the OS serial port of controller A.
  • b: switches to the OS serial port of controller B.
2. In manual mode, the value is ao, bo, ab, bb, or mgt, where:
  • ao: switches to the OS serial port of controller A.
  • bo: switches to the OS serial port of controller B.
  • ab: switches to the BMC serial port of controller A.
  • bb: switches to the BMC serial port of controller B.
  • mgt: switches to the BMC serial port of the management board.
6 U devices: 1. In automatic mode, the value is a, b, c, or d, where:
  • a: switches to the OS serial port of controller A.
  • b: switches to the OS serial port of controller B.
  • c: switches to the OS serial port of controller C.
  • d: switches to the OS serial port of controller D.
2. In manual mode, the value is ao, bo, co, do, ab, bb, cb, db, or mgt, where:
  • ao: switches to the OS serial port of controller A.
  • bo: switches to the OS serial port of controller B.
  • co: switches to the OS serial port of controller C.
  • do: switches to the OS serial port of controller D.
  • ab: switches to the BMC serial port of controller A.
  • bb: switches to the BMC serial port of controller B.
  • cb: switches to the BMC serial port of controller C.
  • db: switches to the BMC serial port of controller D.
  • mgt: switches to the BMC serial port of the management board.
ARM system: 2 U devices: 1. In manual mode, the value is os or bmc, where:
  • os: switches to the OS serial port of controller.
  • bmc: switches to the BMC serial port of controller.
4 U devices: 1. In automatic mode, the value is a, b, c, or d, where:
  • a: switches to the OS serial port of controller A.
  • b: switches to the OS serial port of controller B.
  • c: switches to the OS serial port of controller C.
  • d: switches to the OS serial port of controller D.
2. In manual mode, the value is ao, bo, co, do, ab, bb, cb, or db, where:
  • ao: switches to the OS serial port of controller A.
  • bo: switches to the OS serial port of controller B.
  • co: switches to the OS serial port of controller C.
  • do: switches to the OS serial port of controller D.
  • ab: switches to the BMC serial port of controller A.
  • bb: switches to the BMC serial port of controller B.
  • cb: switches to the BMC serial port of controller C.
  • db: switches to the BMC serial port of controller D.

Modes

serial port mode

Usage Guidelines

1. Serial ports on management board A can be switched to serial ports on controller B/D or those on management board A.

2. Serial ports on management board B can be switched to serial ports on controller A/C or those on management board B.

Example

  • Switch to the OS serial port of controller A manually on a 6 U management board. The command output varies depending on a specific product.

    administrator@SMM_6U / # switch ao
  • Switch to the OS serial port of controller A manually on a 4 U controller board. The command output varies depending on a specific product.

    iBMC:/->switch ao

System Response

None

Translation
Download
Updated: 2020-01-17

Document ID: EDOC1000181602

Views: 751771

Downloads: 64

Average rating:
This Document Applies to these Products

Related Version

Related Documents

Share
Previous Next