This document is applicable to OceanStor 18500 V5, 18800 V5, 18500F V5, and 18800F V5. Based on the CLI, this document describes how to use various commands classified by functions and how to set the CLI and manage the storage system through these commands. The document that you browse online matches the latest C version of the product. Click Download to download documents of other C versions.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
change rtt_switch general

change rtt_switch general

Function

The change rtt_switch general command is used to manually configure the REQ time switch for an item.

Format

change rtt_switch general trace_id=? status=?

Parameters

Parameter

Description

Value

trace_id=?

The ID of item.

The value ranges from 0 to 65536 or all.

status=?

The switch for an item.

The value can be "open" or "close", where:

1."open": the switch for an item will be enabled.

2."close": the switch for an item will not be enabled.

Views

Developer view

Usage Guidelines

  • This command is effective for the local controller and does not affect the remote controller.
  • System performance reduces if the REQ time switch for all items is enabled. Therefore, exercise caution when enabling the REQ time switch for all items.

Example

  • To enable the REQ time switch for the item whose trace_id is 100, run the following command.
    developer:/>change rtt_switch general trace_id=100 status=open 
    Command executed successfully.
  • To disable the REQ time switch for the item whose trace_id is 20, run the following command.
    developer:/>change rtt_switch general trace_id=20 status=close 
    Command executed successfully.

System Response

None