This document is applicable to OceanStor 18500 V5, 18800 V5, 18500F V5, and 18800F V5. Based on the CLI, this document describes how to use various commands classified by functions and how to set the CLI and manage the storage system through these commands. The document that you browse online matches the latest C version of the product. Click Download to download documents of other C versions.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
show pair log_ctrl

show pair log_ctrl

Function

The show pair log_ctrl command is used to query the number of concurrent dual-write I/Os and waiting I/Os of a pair module.

Format

show pair log_ctrl [ controller=? ]

Parameters

Parameter

Description

Value

controller=?

Controller ID.

The value is in the format of "XA" or "XB" or "XC" or "XD", where the "X" is an integer ranging from 0 to 3, for example: "0A", "1C".

Views

Developer view

Usage Guidelines

The command is executed on the local controller by default.

Example

Querying the number of concurrent dual-write I/Os and waiting I/Os of the current pair module.

developer:/>show pair log_ctrl 
Total Count  Current Count  Object ID  Logic Address  Length  Operate Code  Flying Count  Code Flag        
  -----------  -------------  ---------  -------------  ------  ------------  ------------  -------------- 
  85           0              14         497568         1       320962560     1             PAIR_TYPE_NONE 
  85           0              12         497957         1       320962560     1             PAIR_TYPE_NONE 
  85           0              13         497945         1       320962560     1             PAIR_TYPE_CLN 
  85           0              13         497948         1       320962560     1             PAIR_TYPE_CLN 
  85           0              13         497952         1       320962560     1             PAIR_TYPE_CLN 
  85           0              13         497947         1       320962560     1             PAIR_TYPE_CLN 
  85           0              15         497560       1       320962560     1             PAIR_TYPE_CLN 
  85           0              15         497565         1       320962560     1             PAIR_TYPE_CLN

System Response

The following table describes the parameter meanings.

Parameter

Meaning

Total Count

Maximum number of dual-write I/Os supported by the system.

Current Count

Number of available concurrent dual-write I/Os.

Object ID

ID of the accessed object.

Logic Address

Accessed start sector.

Length

Start sector of access.

Operate Code

Operation code of an I/O.

Flying Count

Count of references.

Code Flag

Operation type of an I/O.

Translation
Download
Updated: 2019-07-11

Document ID: EDOC1000181602

Views: 633660

Downloads: 56

Average rating:
This Document Applies to these Products
Related Version
Related Documents
Share
Previous Next