Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
xnet threadinfo

xnet threadinfo

Function

The xnet threadinfo command is used to query information about monitoring threads.

Format

xnet threadinfo -usermode

Parameters

Parameter

Description

Value

usermode This parameter is mandatory. It must be added to the end of a command as a suffix to query user state information.

The value can be:

  • "-app_data": executes the command for the app_data process.
  • "-devm": executes the command for the devm process.
  • "-sys_app": executes the command for the sys_app process.
  • "-cfg_app": executes the command for the cfg_app process.

Views

Diagnostic view

Usage Guidelines

OceanStor 18500 V5 Kunpeng, 18500F V5 Kunpeng, 18800 V5 Kunpeng and 18800F V5 Kunpeng storage systems support this command.

Example

Query information about monitoring threads.

admin:/diagnose>xnet threadinfo -app_data
name           tid         start_time  end_time    run_nums    
xnet_timer_12  30929       4311423127  4311423127  657497      
xnet_conn_mgr_12 30931       4311423140  4311423140  1377690     
xnet_conn_mgr_12 30932       4311423139  4311423139  1380650     
xnet_conn_mgr_12 31025       4311423140  4311423140  1380842     
xnet_conn_mgr_12 31023       4311423139  4311423139  1412376

System Response

The following table describes the parameter meanings.

Parameter

Meaning

name

Thread name.

tid

Thread ID.

start_time

Start time.

end_time

End time.

run_nums

Running time.

Translation
Download
Updated: 2020-01-17

Document ID: EDOC1000181602

Views: 763230

Downloads: 66

Average rating:
This Document Applies to these Products

Related Version

Related Documents

Share
Previous Next