Advanced O&M Command Reference

OceanStor 18000 and 18000F V5 Series V500R007

This document is applicable to OceanStor 18500 V5, 18800 V5, 18500F V5, and 18800F V5. Based on the CLI, this document describes how to use various commands classified by functionsand how to set the CLI and manage the storage system through these commands.

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
sys showfailedflowtrace

sys showfailedflowtrace

Function

The sys showfailedflowtrace command is used to query the information about a failed object flow.

Format

sys showfailedflowtrace

Parameters

None

Views

Diagnostic view

Usage Guidelines

None

Example

Query the information about a failed object flow.

ibc_os_hs:/diagnose>sys showfailedflowtrace
   ID          Date Time             Flowid: Failed Flow Name             Phaseid: Failed Phase Name            Stepid: Failed Step Name            Failed Action Name      
 ------  ---------------------  -----------------------------------  -----------------------------------  -----------------------------------  -----------------------------------
 [0000]  [2017-07-12 16:07:45]  3  : FLOW_OBJ_NODE_FAULT_BEFORE      0  : switch_L2Cache_service_phase    0  : SYS     reclaim resource        NodeFault: GetVnodeLock                 
 [0001]  [2017-07-12 16:07:45]  3  : FLOW_OBJ_NODE_FAULT_BEFORE      0  : switch_L2Cache_service_phase    0  : SYS     reclaim resource        NodeFault: FreeVnodeLock                
 

System Response

The following table describes the parameter meanings.

Parameter

Meaning

ID

Failed object flow ID.

Date Time

Time when a flow fails.

Flowid: Failed Flow Name

ID and name of a failed flow.

Phaseid: Failed Phase Name

ID and name of a failed flow execution phase.

Stepid: Failed Step Name

ID and name of a failed flow execution step.

Failed Action Name

Name of a failed flow action.

Translation
Download
Updated: 2020-01-17

Document ID: EDOC1000181602

Views: 750705

Downloads: 64

Average rating:
This Document Applies to these Products

Related Version

Related Documents

Share
Previous Next