No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Advanced O&M Command Reference

OceanStor 18000 and 18000F V5 Series V500R007

This document is applicable to OceanStor 18500 V5, 18800 V5, 18500F V5, and 18800F V5. Based on the CLI, this document describes how to use various commands classified by functionsand how to set the CLI and manage the storage system through these commands.

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
drveth showsfginfo

drveth showsfginfo

Function

The drveth showsfginfo command is used to view information about the optical module in a physical port on a network adapter.

Format

drveth showsfginfo portid

Parameters

Parameter

Description

Value

portid Physical port ID.

-

Views

Diagnostic view

Usage Guidelines

None

Example

View information about the optical module in a physical port on a network adapter.

admin:/diagnose>drveth showsfginfo 0x22000
Vender name:AVAGO
Vender OUI: 00176a
Serial Num: AA1152AEMWE
Date: 20111227
Bitrate: 10300
Los: no
Tx fault: no
Tx dis: no
Tx soft-dis:no
Rx rate : yes
Rx soft-rat:no
Temperature:34
Tx pow(uW): 542
Tx bias(uA): 6820
Rx pow(uW): 593
temp high warning: 80
temp low warning: 0
temp test pass
Tx high warning: 790
Tx low warning: 317
Tx power test pass
Rx high warning: 790
Rx low warning: 102
Rx power test pass

System Response

The following table describes the parameter meanings.

Parameter

Meaning

Vender name

Vendor name of the optical module.

Vender OUI

Vendor organizationally unique identifier (OUI) of the optical module.

Serial Num

Optical module SN.

Date

Delivery date of the optical module.

Bitrate

Maximum physical rate of the optical module.

Los

LOS signal alarm of the optical module.

Tx fault

Packet sending failure of the optical module.

Tx dis

Identifier of enabled or disabled optical power sending of the optical module.

Tx soft-dis

Identifier of enabled or disabled optical power sending of the optical module software.

Rx rate

Selection rate of the optical module.

Rx soft-rat

Rate of the optical module software.

Temperature

Current temperature of the optical module.

Tx pow(uW)

Optical power sent by the optical module.

Tx bias(uA)

Bias current sent by the optical module.

Rx pow(uW)

Optical power received by the optical module.

temp high warning

Upper limit of temperature alarm generating of the optical module.

temp low warning

Lower limit of temperature alarm generating of the optical module.

temp test

Temperature test result of the optical module.

Tx high warning

Upper limit of an alarm about optical power sending of the optical module.

Tx low warning

Lower limit of an alarm about optical power sending of the optical module.

Tx power test

Test result of optical power sending of the optical module.

Rx high warning

Upper limit of an alarm about optical power receiving of the optical module.

Rx low warning

Lower limit of an alarm about optical power receiving of the optical module.

Rx power test

Test result of optical power receiving of the optical module.

Translation
Download
Updated: 2020-01-17

Document ID: EDOC1000181602

Views: 743118

Downloads: 59

Average rating:
This Document Applies to these Products

Related Version

Related Documents

Share
Previous Next