Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
show lun cache_sequence_flow

show lun cache_sequence_flow

Function

The show lun cache_sequence_flow command is used to query configuration information about the cache sequence flow of a LUN.

Format

show lun cache_sequence_flow lun_id=?

Parameters

Parameter

Description

Value

lun_id LUN ID.

To obtain the value, run "show lun general".

Views

Developer view

Usage Guidelines

N/A.

Example

Query configuration information about the cache sequence flow of LUN "0".

admin:/>show lun cache_sequence_flow lun_id=0
bitmap                         :16
counter                        :64
distance                       :64
time                           :120
algorithm Switch               :1
minimum prefetch threshold     :16
interval prefetch multiple     :32  
maximum prefetch length        :8192
minimum prefetch length        :0

System Response

The following table describes the parameter meanings.

Parameter

Meaning

bitmap

Sequence flow identification bitmap.

counter

Sequence degree count.

distance

Sequence flow identification distance.

time

Sequence flow failure period.

algorithm switch

Switch of the sequence flow adaptive algorithm.

minimum prefetch threshold

Lower threshold of the sequence flow prefetch.

interval prefetch multiple

Prefetch multiplier of interval sequence flows.

maximum prefetch length

Maximum prefetch length of sequence flow identification.

minimum prefetch length

Minimum prefetch length of sequence flow identification.