Advanced O&M Command Reference

OceanStor 18000 and 18000F V5 Series V500R007

This document is applicable to OceanStor 18500 V5, 18800 V5, 18500F V5, and 18800F V5. Based on the CLI, this document describes how to use various commands classified by functions and how to set the CLI and manage the storage system through these commands. The document that you browse online matches the latest C version of the product. Click Download to download documents of other C versions.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
rephc showstartinfo

rephc showstartinfo

Function

The rephc showstartinfo command is used to query the kickoff marker bit status of HyperMetro pairs.

Format

rephc showstartinfo

Parameters

None

Views

Diagnostic view

Usage Guidelines

None

Example

Query the kickoff marker bit status of HyperMetro pairs.

admin:/diagnose>rephc showstartinfo 
Show rephc mod spec:  
 isRepHcStart         :1  
 dbId                 :11  
 isDbOpenFail         :0  
 domain state         :5  
 isCgStartFail        :0  
 isCgStart            :0  
 isCgCtrlStart        :0  
 isNeedMstToNormal :0  
 isNeedNormalToMst :0

System Response

The following table describes the parameter meanings.

Parameter

Meaning

isRephcStart

Whether HyperMetro starts to work.

dbId

ID of the HyperMetro database.

isDbOpenFail

Whether the database fails to be started.

domainState

Service status of the HyperMetro domain module.

isCgStartFail

Whether the consistency group fails to be started.

isCgStart

Whether the services of the consistency group have been started.

isCgCtrlStart

Whether the memory has been recovered in the consistency group.

isNeedMstToNormal

Whether the master node in the cluster is changed to a normal node.

isNeedNormalToMst

Whether a normal node in the cluster is changed to the master node.