Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
xrb iomstat

xrb iomstat

Function

The xrb iomstat command is used to collect information about IOPS during the specified period.

Format

xrb iomstat -t time

Parameters

Parameter

Description

Value

time Sets a statistical period (unit: second).

The value is an integer between 1 and 120.

Views

Diagnostic view

Usage Guidelines

  • To run the command, you must set a statistics period and the period cannot exceed 120 seconds.
  • Only after the statistical period runs out, you can perform the next collection operation.

Example

Set the statistical period to 10 seconds and start collecting information.

admin:/diagnose> xrb iomstat -t 10  
RDMA iom on success.
Please wait (10000)ms and check the result.

System Response

None